Product Description
The Radio Frequency Electrosurgical Unit YR02149 stands as a revolutionary tool in modern surgical procedures, combining precision and efficiency. Its highly skilled technology operates in various modes, including Monopolar Cut, Monopolar Coag, Bipolar Cut, and Bipolar Coag. This versatility ensures it caters to a wide range of surgical needs, making it an indispensable asset in both general and specialized surgical environments.
Crafted for precision, this device enhances surgical outcomes by offering various power settings adjusted for different tissue types and procedures. The unit’s technical specifications highlight its robust capabilities:
| Model | YR02149 | |
| Working Mode | Max Power / Rated Load | |
| Monopolar Cut | Pure cut | 120W / 500Ω |
| Blend 1 | 90W / 500Ω | |
| Blend 2 | 80W / 500Ω | |
| Monopolar Coag | Fulgurate Coag | 60W / 500Ω |
| Spray Coag | 40W / 500Ω | |
| Bipolar Cut | Bipolar Cut | 60W / 100Ω |
| Bipolar Coag | Bipolar Coag | 60W / 100Ω |
| Electrical requirement | Monopolar Measuring Frequency | 4.0MHZ ±2% |
| Bipolar Measuring Frequency | 1.84MHZ ±2% | |
| Max Input Currency | 1400VA | |
| Environmental Conditions for Use | Condition | Range |
| Temperature | 50°C to 40°C | |
| Relative humidity | ≤ 95% non-condensing | |
| Pressure | 700 hPa to 1060 hPa | |
Market Price
When it comes to acquiring advanced surgical equipment like the Radio Frequency Electrosurgical Unit YR02149, price is a critical factor for medical facilities. The market offers this cutting-edge unit within a competitive range. With an average market price ranging from $4500 to $5400 USD, this unit provides significant value given its advanced features and capabilities.
Healthcare institutions seeking top-tier technology at a reasonable investment will find this electrosurgical unit an attractive option that aligns with their budgetary considerations. For exact pricing details, users are encouraged to inquire for a quote, capitalizing on special offers and promotions available through the Kalstein Plus platform.
Frequently Asked Questions
What are the main uses of the YR02149 Electrosurgical Unit?
This unit is primarily used in surgical procedures requiring precise cutting and coagulation. It is suitable for various operations in both monopolar and bipolar modes.
Is the device easy to operate?
Yes, the electrosurgical unit YR02149 is designed with user-friendly controls that simplify operation, making it accessible for healthcare professionals with varying levels of experience.
How can I ensure the safety of this equipment during use?
The YR02149 includes multiple safety features such as monitoring frequencies and power settings to ensure safe and controlled usage. Regular maintenance and compliance with operational guidelines further enhance safety.
Advantages and Disadvantages
One of the primary advantages of the YR02149 is its versatility, offering multiple modes for different surgical requirements. This adaptability contributes to enhanced surgical outcomes and procedural efficiency. Additionally, the unit’s impeccable design ensures durability and long-term utility.
However, potential disadvantages include the initial learning curve for professionals unfamiliar with electrosurgical technology. Also, the price point, while competitive, may require thoughtful budgeting for smaller healthcare facilities. Despite these considerations, the advanced features and reliability significantly outweigh any potential drawbacks.
Product Use in the Field
In practical applications, the Electrosurgical Unit YR02149 demonstrates remarkable performance across various surgical scenarios. It is frequently used in hospitals and clinics for procedures requiring precise cutting and coagulation. Its ability to switch effortlessly between monopolar and bipolar modes ensures its applicability in diverse operations.
Surgeons utilize this device to improve incision precision and minimize tissue damage, significantly reducing recovery times for patients. Its robust construction and technology mean it can withstand the demands of busy medical environments while maintaining optimal performance.
Recommendations
For optimal use, it is recommended to regularly calibrate and maintain the YR02149 according to manufacturer guidelines. Ensuring that the device is operated within its specified environmental conditions will prolong its lifespan and maintain its efficiency.
Additionally, user training should be prioritized to familiarize surgical staff with the unit’s features and ensure safer operation. Employing these strategies will maximize the benefits derived from this essential piece of surgical equipment.
If you’re seeking a blend of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life, it’s time to become part of our community. Explore more about the YR02149 here.