Product Description
The Chemiluminescence Imager Mini, models YR06065 and YR06066, is designed for high-resolution imaging in laboratory settings. Both models are equipped with a cooled CCD camera, delivering an impressive physical resolution of 6 Megapixels, 2750×2200, and ensuring detailed, crisp imaging.
Notably, the YR06065 features a Sensitive F0.95 lens, while the YR06066 takes imaging sensitivity a step further with an Ultra-sensitive F0.8 lens. This distinction allows users to select the model that best suits their specific application needs. The pixel density in both models is 16 Bit, with a vast dynamic range of ≥4.6OD and a grey scale spectrum of 65,536 shades, providing exceptional image depth and clarity.
The imager’s cooling system is engineered to maintain a temperature of -60℃ below ambient conditions, with regulation possible up to -30℃, ensuring stable performance even in demanding environments. The product comes with inclusive image acquisition and analysis software, which does not require a dongle, allowing unlimited users with free updates, thus maximizing accessibility and long-term utility.
Model | YR06065 | YR06066 |
Digital Camera | Cooled CCD Camera | |
Physical Resolution | 6 Megapixels,2750*2200 | |
Pixel Density and A/D | 16 Bit | |
Grey Scales | 65536 | |
Dynamic Range | ≥4.6OD | |
Cooling Temperature | -60℃ below ambient, -30℃ regulated | |
Scientific Lens | Sensitive F0.95 Lens | Ultra sensitive F0.8 Lens |
Image Acquisition Software | No software dongle required, unlimited users, free update | |
Image Analysis Software | No software dongle required, unlimited users, free update |
Market Price
While the exact price of the Chemiluminescence Imager Mini models starts around 21,400 USD, the average market price can range from approximately 21,000 to 22,200 USD depending on specific retailer offers and potential additional features or services included in the purchase. It is wise to explore options and request quotes to secure the best available price for your laboratory needs.
Frequently Asked Questions
What are the key differences between the YR06065 and YR06066 models?
The primary difference lies in the lenses: the YR06065 comes with a Sensitive F0.95 Lens, while the YR06066 is equipped with an Ultra-sensitive F0.8 Lens, allowing for improved sensitivity in imaging applications.
Is the software included with the purchase?
Yes, the image acquisition and analysis software is included with the purchase of both models. The software does not require a dongle, supports unlimited users, and includes free updates.
What is the cooling capacity of the device?
The cooling system is capable of maintaining temperatures at -60℃ below ambient, regulated up to -30℃, ensuring optimal performance in a range of conditions.
Advantages and Disadvantages
Advantages: The Chemiluminescence Imager offers high-resolution capabilities with a 6 Megapixel camera, exceptional grey scales of 65,536, and a dynamic range of ≥4.6OD. Its user-friendly software, which allows unlimited users and free updates, provides flexibility and ease of use.
Disadvantages: The high cost may be prohibitive for smaller labs or educational settings with limited budgets. Furthermore, the advanced features may require additional training for users unfamiliar with such sophisticated equipment.
Use of the Product in the Field
The Chemiluminescence Imager Mini is crucial in fields requiring precise and reliable imaging, such as biomedical research, pharmaceuticals, and advanced material studies. Its excellent resolution and sensitivity allow scientists to capture detailed images of samples, providing insights critical in experiments and analyses.
Due to its advanced cooling system, the device is well-suited for use in highly variable temperature environments, ensuring continuous and reliable performance. The device’s ease of use also supports educational settings where advanced students and educators can perform sophisticated imaging tasks.
Recommendations
To ensure long-term, optimal performance of the Chemiluminescence Imager, it is recommended to regularly clean the lens and maintain the cooling system by following the manufacturer’s guidelines. Ensuring software updates are applied promptly will also enhance functionality and security.
Consider participating in available training sessions or consulting expert users to fully leverage the advanced features of this device. For those looking to fit this imager into a budget, consider initiating a quotation on the Kalstein Plus platform to explore favorable acquisition options.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our online purchasing channels, intuitive and fast, are designed for your convenience, ensuring the most user-friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/chemiluminescence-imager-mini-yr06065-yr06066/.