Product Description
The YRA401 Washing Solution stands out in the realm of clinical immunoassay analyzers as a highly efficient and essential component for ensuring the optimal performance of diagnostic systems. This meticulously formulated solution is specially designed for use in CLIA (chemiluminescent immunoassay) systems, playing a pivotal role in the separation and cleaning of reagents. Each bottle delivers a substantial volume of 500 ml, translating into approximately 300 tests, making it a cost-effective choice for laboratories.
The YRA401 boasts a composition of Tris, NaCl, and surfactant, granting it superior cleaning capabilities. With a recommended dilution ratio of 1:20, using pure water, the solution ensures effective decontamination without leaving residues. Its non-toxic and non-polluting properties adhere to environmental safety standards, while its high stability makes it ideal for extended storage and consistent performance.
Model | YRA401 |
Product Format | Washing Solution for Clinical Immunoassay Analyzers |
Volume per Bottle | 500 ml |
Performance | 300 tests per bottle |
Recommended Dilution | 1:20 (use pure water) |
Composition | Tris, NaCl, surfactant |
Properties | High cleanability, easy to use, non-toxic, non-polluting, highly stable. |
Intended Use | Dedicated to the CLIA system for the separation and cleaning of reagents. |
Market Price
The market positioning of the YRA401 Washing Solution reflects its premium formulation and efficiency in the laboratory context. Generally, similar solutions range in price depending on volume and specific formulation details. The YRA401 is competitively priced in the mid-range category, offering significant value considering its high yield of 300 tests per bottle.
While specific prices can vary based on distributor and geographical location, potential buyers are encouraged to contact suppliers directly for precise pricing. For those looking to streamline their procurement process, a quote can be easily obtained through the Kalstein Plus platform, providing tailored pricing that fits your laboratory’s budgetary requirements.
Frequently Asked Questions
How do I properly dilute the YRA401 solution?
The recommended dilution for the YRA401 Solution is 1:20 using pure water. This ratio ensures maximum cleaning effectiveness and system efficiency.
Is the YRA401 solution safe for the environment?
Yes, the YRA401 is formulated to be non-toxic and non-polluting, making it safe for use in laboratories that prioritize environmental sustainability.
Can the solution be used with different analyzer brands?
The YRA401 is primarily designed for use with CLIA systems. It is recommended to consult with the equipment manufacturer to ensure compatibility.
Advantages and Disadvantages
The YRA401 Washing Solution offers several noteworthy advantages. Its high cleanability ensures that immunoassay analyzers remain in top operational condition, minimising the risk of result contamination or degradation. The solution’s composition is engineered for stability and extended shelf life, which supports consistent laboratory workflows.
However, like any technical product, it may present certain limitations. Some laboratories may require solutions with specific properties tailored to particular equipment brands. It’s crucial to ensure compatibility with your specific immunoassay systems before transitioning to YRA401. Additionally, while the solution is cost-effective on a per-test basis, initial purchase may require budget adjustments for cost-sensitive settings.
Product Use in the Field
In practical scenarios, the YRA401 is employed extensively in clinical laboratories engaged in routine immunoassays. Before use, the solution is diluted to the recommended concentration, after which it is applied in the machine’s automated cycle, ensuring precise and thorough cleaning of essential system components.
Technicians rely on the consistency of YRA401 to maintain the integrity of assay results. The solution supports seamless operation, reducing downtime linked to maintenance by efficiently preventing contamination build-up. Laboratories prioritizing high throughput and result accuracy find YRA401 indispensable in their daily operations.
Recommendations
For laboratories planning to integrate the YRA401 Washing Solution, it is advisable to initiate with a test run to confirm compatibility with existing analyzers. Ensure personnel are trained on proper dilution and usage procedures to maximize the solution’s efficacy. Regular monitoring and calibration of analyzers should continue to ensure optimal results are obtained consistently.
Maintaining a sufficient inventory of the YRA401 solution will mitigate potential supply chain disruptions, allowing lab operations to proceed uninterrupted. To facilitate easy reordering and manage expenses, consider using the Kalstein Plus platform for automated quotations and order processing, streamlining laboratory procurement logistics efficiently.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each equipment with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/system-washing-solution-yra401/.