Advanced Infant Phototherapy Unit: Key Features and Market Insight

Product Description

The Infant Bilirubin Phototherapy Unit YR02195 is an advanced medical device designed to offer effective treatment for neonatal jaundice. The unit is characterized by its use of a blue tube light source, which ensures optimal performance across a wavelength spectrum of 400-550nm. This blue light is critical in reducing bilirubin levels in newborns, allowing for a safe and efficient treatment process.

The 1000 hours lifespan of the light source ensures prolonged use, minimizing maintenance needs and maximizing uptime in clinical settings. The unit operates with an input power of less than 150VA, emphasizing its energy efficiency while ensuring effective performance. Designed to reduce noise pollution, the unit operates at ≤55dB(A), making it suitable for quiet environments like neonatal intensive care units.

The YR02195 model features a broad effective treatment area of 1125px×600px, providing ample space to ensure comprehensive care delivery. The unit is adjustable, with light sources that can be angled at 30°, 60°, or 90°, and a height adjustment range of 1100mm to 1500mm, allowing healthcare providers to position the device optimally for each patient.

Model YR02195
Input power <150VA
Light source Blue tube
Light source effective life 1000 hours
Wave length 400-550nm
Irradiance treatment distance 10~500px
Effective area 1125px×600px
Infrared radiation in effective area ≤10mW/cm2(760nm<λ≤1400nm)
Ultraviolet radiation in effective area ≤1.0×10-5mW/cm2 (180nm<λ≤400nm)
Operate noise ≤55dB(A)(ambit noise is lower than 40dB(A))
Basic performance ≥500μW/cm2
Adjust angle 30°,60°,90°
Adjust height 1100mm~1500mm

Market Price

The Infant Bilirubin Phototherapy Unit YR02195 is competitively priced in the market. With a substantial average market range between 700 USD and 1500 USD, this unit provides an excellent balance of affordability and high-end features. For personalized pricing details or to learn about exclusive offers, potential buyers are encouraged to explore the Kalstein Plus platform for a customized quote.

Frequently Asked Questions

What is the lifespan of the light source in the YR02195 model?

The light source in the YR02195 model has an effective lifespan of up to 1000 hours, ensuring long-term use without the need for regular replacements.

Can the height and angle of the phototherapy unit be adjusted?

Yes, the Infant Bilirubin Phototherapy Unit is designed to accommodate varying treatment needs with adjustable angles of 30°, 60°, and 90°, as well as a height range of 1100mm to 1500mm.

Is this unit suitable for all neonatal care settings?

Absolutely. The YR02195 model, with its low noise operation and efficient light source, is well-suited for various neonatal environments, including intensive care units.

Advantages and Disadvantages

Advantages:

  • The YR02195 model offers energy efficiency with an input power of less than 150VA.
  • It provides a high level of irradiance, with basic performance at ≥500μW/cm2, ensuring effective neonatal jaundice treatment.
  • The unit features easy adjustability for both height and angle, facilitating optimal positioning for any patient setup.
  • Its low operation noise of ≤55dB(A) is ideal for maintaining a calm atmosphere in neonatal care environments.

Disadvantages:

  • The blue tube light source, while efficient, will require replacement after reaching its maximum lifespan of 1000 hours.
  • Care must be taken to ensure minimum exposure beyond prescribed treatment times, as with all phototherapy treatments.

Use of the Product in the Field

The Infant Bilirubin Phototherapy Unit YR02195 is widely used in hospital neonatal care wards, particularly for the treatment of neonatal jaundice. This condition, which results in a yellowing of the skin and eyes due to high bilirubin levels, is managed effectively with light therapy. The YR02195 unit emits a blue light that aids in breaking down bilirubin in the infant’s body, thus speeding up its natural clearance through the liver.

Clinical practitioners appreciate the unit’s easy-to-use interface and adjustable settings that allow for customization based on each infant’s specific treatment needs. The device’s efficient light source and ergonomic design ensure it integrates smoothly into various healthcare settings, providing reliable support in critical care scenarios.

Recommendations

For optimal performance of the Infant Bilirubin Phototherapy Unit YR02195, it is recommended to follow the manufacturer’s instructions regarding operational settings and maintenance. Regularly check the effectiveness of the light source and replace it as needed to maintain optimal treatment efficacy. Ensure that the unit is cleaned and sanitized regularly to adhere to hygiene standards.

Healthcare professionals should be trained on the correct positioning of the unit to maximize the exposure of the affected area while minimizing any potential discomfort to the infant. Additionally, clinical staff should monitor infants closely during treatment to observe any possible adverse reactions and make necessary adjustments swiftly.

If you are looking for a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a high level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate anymore, we bring science to life, it’s time to be part of our community. https://kalstein.net/en/product/infant-bilirubin-phototherapy-unit-yr02195/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]