Description of the Product
The Total Organic Carbon Analyzer models YR04947 and YR04948 are cutting-edge devices designed to give precise and reliable measurements of total organic carbon (TOC) in various samples. With a remarkable detection range of 0.001-1.500 mg/l (ppm), these analyzers are capable of thoroughly evaluating the carbon content across different applications. Both models demonstrate a minimal detection limit of 1 ppb, ensuring exceptional sensitivity. Their maximum tolerance of ±5% further indicates accuracy in analytical results.
One of the standout features of these analyzers is their rapid analysis time of 3 minutes, supported by a response time of within 10 minutes. Designed to function across a broad sample temperature range of 1-95℃, these devices are versatile platforms suitable for multiple types of environments. They work optimally in an ambient temperature environment between 10-40℃, with a temperature fluctuation tolerance of ±5℃/d. As such, these devices are well-equipped to handle laboratory settings’ rigorous and exacting nature.
Model | YR04947 | YR04948 |
Detection range | 0.001-1.500mg/l (ppm) | |
Detection limit | 1ppb | |
Max tolerance | ±5% | |
Analysis time | 3 min | |
Response time | within 10 min | |
Sample temperature | 1-95℃ | |
Environment temperature | 10-40℃ with temperature change ±5 ℃/d | |
Sample flow speed | 3ml/min | |
Relative humidity | ≤85% | |
Repeatability tolerance | ≤3% | |
Drifting | ±5% | |
Power Supply | AC 220V,50/60Hz or AC 110V | |
Frequency | 50/60Hz | |
Rated Power | 100W | |
Dimension | 440*220*300mm |
Market Price
In today’s market, the Total Organic Carbon Analyzer, with its state-of-the-art capabilities, has a price range that begins at approximately $18,500 and can extend to about $19,500. This range reflects the technology’s sophistication and the analytical precision it offers. Interested buyers should consider that this investment aligns with the long-term benefits of accurate and reliable TOC measurements, especially in environments where precision is paramount. For specific pricing, we highly encourage potential purchasers to request a personal quote through our intuitive Kalstein Plus platform.
Frequently Asked Questions
What is the primary application of the Total Organic Carbon Analyzer?
These analyzers are primarily used to measure the concentration of organic carbon in both water and wastewater, essential for various environmental and industrial applications.
How does temperature affect the analyzer’s performance?
The device is engineered to perform optimally at sample temperatures between 1-95°C and environmental temperatures ranging from 10-40°C, accommodating a flexibility in operation within these ranges.
Can the analyzer handle fluctuating environmental conditions?
Yes, it can operate effectively under conditions where the temperature changes up to ±5°C per day, demonstrating strong adaptability to different environments.
Advantages and Disadvantages
The Total Organic Carbon Analyzer stands out for several notable advantages. Its rapid analysis time and high sensitivity make it an indispensable tool for laboratories requiring fast and reliable TOC measurements. Additionally, its ability to operate across a broad temperature range enhances its application versatility, adapting to various environmental conditions seamlessly. Conversely, one potential disadvantage is the initial acquisition cost, which, although justified by the unit’s performance, may be considered significant for some laboratories with limited budgets.
Another aspect to consider is the maintenance and operation training required to utilize the device fully. These factors, while common in sophisticated laboratory equipment, should be considered when planning the implementation of TOC analysis equipment in a new setting.
Product Usage in the Field
In practical field scenarios, the Total Organic Carbon Analyzer is indispensable for laboratory analysts and environmental scientists monitoring water quality. This equipment is crucial in assessing the purity of drinking water and the treatment efficiency in wastewater management. Flowing with precision at 3ml/min, the analyzer ensures consistent and dependable sample throughput, critical in high-demand testing environments.
These machines also find significant utility in industrial applications where managing organic content in effluents is necessary for environmental compliance. Whether used in environmental research, municipal water treatment plants, or industrial settings, this analyzer plays a vital role in ensuring water quality standards are consistently met.
Recommendations
To maximize the longevity and effectiveness of the Total Organic Carbon Analyzer, it is recommended that users adhere to a regular maintenance schedule, including calibration and cleaning protocols as outlined in the user manual. Operators should be fully trained in proper sample handling and device operation to minimize errors and prolong the lifespan of the equipment. Furthermore, users are encouraged to exploit the analyzer’s full potential by leveraging the data management capacities often included with advanced models.
For tailored application support and specific advice concerning the Total Organic Carbon Analyzer, interested clients are invited to inquire directly through Kalstein Plus, where expert assistance and hassle-free quotes are at their fingertips.
If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a high level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life. It’s time to become part of our community. https://kalstein.net/en/product/total-organic-carbon-analyzer-yr04947-yr04948/.