Product Description
The YR05728 Laminar Air Flow Clean Bench is a pioneering solution designed to meet the stringent requirements of various laboratory environments. This state-of-the-art equipment is engineered to create a contaminant-free work zone, thanks to its advanced laminar flow technology that ensures the highest level of air purity. With a cleanliness level of Class 100@≥0.5μM (US Federal 209E), it guarantees an environment suitable for sensitive experimental tasks.
One of the standout features of the YR05728 model is its optimal airflow, with an average wind speed ranging from 0.25 to 0.45 m/s. This controlled airflow is crucial for maintaining a sterile working area, minimizing the risk of contamination. The clean bench also boasts a low noise level of ≤62dB(A), ensuring a quiet working environment, which is particularly important in research settings where concentration is key. Additionally, the vibration half peak is maintained at ≤5μM across x, y, and z directions, providing a stable platform for precise laboratory work.
| Model | YR05728 |
| Cleanliness Level | Class 100@≥0.5μM (US Federal 209E) |
| Number of Colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) |
| Average Wind Speed | 0.25~0.45m/s |
| Noise | ≤62dB(A) |
| Vibration half peak | ≤5μM(x、y、z direction) |
| Illuminance | ≥300Lx |
| Power Supply | AC single phase 220V/50Hz |
| Maximum Power | 490W |
| Weight | 90kg |
| Work area size W1×D1×H1 |
880×510×580 1040×690×1600 |
| Dimensions | Single/Single |
| High efficiency filter specification and quantity | 850×565×50 |
Market Price
The YR05728 Laminar Air Flow Clean Bench is competitively priced in the market, with prices typically ranging from $1500 to $2300 USD. This range reflects the high-quality design and performance capabilities of the clean bench, positioning it as a strong contender for laboratories that prioritize precision and cleanliness. Potential buyers can expect a product that delivers exceptional reliability and longevity at a reasonable investment.
Getting a tailored price is just a click away with the Kalstein Plus platform, where potential customers can easily request a quote tailored to their specific needs and quantities.
Frequently Asked Questions
What is the primary function of the YR05728 Laminar Air Flow Clean Bench?
The YR05728 is designed to provide a controlled environment with minimal particle contamination, making it ideal for clean room standards in laboratories.
How does the clean bench maintain air purity?
The bench uses HEPA filtration and precise airflow control to maintain a cleanliness level of Class 100, ensuring a particle-free atmosphere.
Is the noise level disruptive?
Not at all, the unit operates at a very quiet ≤62dB(A), allowing for comfortable, uninterrupted laboratory work.
Advantages and Disadvantages
Advantages
- High Cleanliness: With Class 100 air purity, this clean bench is an excellent choice for sensitive laboratory tasks.
- Low Noise Operation: A noise level of ≤62dB(A) ensures a quiet working environment.
- User Friendly: The design includes ergonomic considerations, enhancing ease of use and workflow efficiency.
Disadvantages
- Space Requirements: The bench may require significant space allocation in smaller lab environments.
- Initial Investment: The upfront cost might be higher in comparison to simpler clean bench models without advanced features.
Product Usage in the Field
In practical scenarios, the YR05728 Laminar Air Flow Clean Bench is invaluable for biotechnology, pharmaceutical, and research laboratories where contamination control is essential. It provides a sterile environment for microbial cultures, tissue culture work, and other critical research activities. Its robust design and ease of manipulation make the YR05728 suitable for both high-precision laboratory tasks and routine applications.
Moreover, the clean bench can be an integral part of preparing sterile solutions, examination of electronic components, or handling sensitive samples. It effectively minimizes contamination risks, ensuring the integrity and reliability of experimental results.
Recommendations
To ensure optimal performance and longevity of the YR05728 Clean Bench, users should follow regular maintenance protocols, including frequent filter checks and replacements as needed. It’s advisable to train laboratory personnel in proper use and handling techniques to prevent damage and maintain the device in peak condition.
Consider integrating the clean bench into a comprehensive laboratory setup that includes regular air quality assessments and procedural audits to maximize its benefits. With the advanced features of the YR05728, laboratories can enhance both the efficiency and reliability of their processes, securing top-tier results in all forms of experimental research.
If you are searching for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a high level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/laminar-air-flow-clean-bench-yr05728/.