Product Description
The Biological Safety Cabinet Class II A2 models YR05704, YR05705, YR05706, and YR05707 are state-of-the-art solutions engineered to provide optimal protection for both the operator and the environment. Designed to comply with Class 100 cleanliness @≥0.5μm as per US Federal Standard 209E, these cabinets ensure that the work area remains sterile, thus minimizing the risk of sample contamination.
These biosafety cabinets feature an average wind speed tailored for precision, with variations set inside the door at 0.38±0.025 m/s, in the middle at 0.26±0.025 m/s, and inside at 0.27±0.025 m/s. The front suction wind speed is fixed at 0.55 m±0.025 m/s, essential for efficient efflux management (30% efflux). Additionally, noise operation is judiciously maintained at ≤65 dB(A), making it an ideal choice for laboratories that require undisturbed workflow.
Model | YR05704 | YR05705 | YR05706 | YR05707 | |
Cleanliness | Class 100@≥0.5μm (US Federal 209E) | ||||
Number of colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) | ||||
Average wind speed | Inside the door | 0.38±0.025m/s | |||
Middle | 0.26±0.025m/s | ||||
Inside | 0.27±0.025m/s | ||||
Front suction wind speed | 0.55m±0.025m/s(30% Efflux) | ||||
Noise | ≤65dB(A) | ||||
Voltage | AC single-phase 220V/50Hz | ||||
Maximum power consumption | 400W | 500W | 600W | 700W | |
Weight | 170KG | 210KG | 250KG | 270KG | |
Working area W1×D1×H1 | 840×650×620 | 1040×650×620 | 1340×650×620 | 1640×650×620 | |
Overall dimension W×D×H | 1000×800×2100 | 1200×800×2100 | 1500×800×2100 | 1800×800×2100 | |
High efficiency filter specification and quantity | 780×490×50× 1 | 520×380×70× 1 | 820×380×70× 1 | 1120×380×70× 1 | |
Specification and quantity of fluorescent lamp/ultraviolet lamp | 12W×1 / 20W×1 | 20W×2/20W×1 | 30W×2/30W×1 | 30W×2/30W×1 |
Market Price
The market price for these state-of-the-art Biological Safety Cabinets typically ranges from $5,500 to $6,600, depending on the specific model and any additional features that may be included. This price range reflects the meticulous engineering and high-quality materials utilized in their construction, ensuring users receive excellent value for their investment. For precise pricing or to request a quote, visit Kalstein’s platform and explore the options available.
Frequently Asked Questions
What class of cleanliness does this cabinet provide?
The Biological Safety Cabinet provides Class 100 cleanliness @≥0.5μm as per US Federal Standard 209E.
How loud are these cabinets?
The operation noise level of the cabinets is ≤65 dB(A), ensuring a quiet working environment.
What is the power consumption of these models?
Power consumption ranges from 400W to 700W depending on the specific model of the biosafety cabinet.
Advantages and Disadvantages
Advantages: These cabinets are equipped with high-efficiency filters and robust airflow mechanisms to guarantee both operator and sample safety. The reduction in noise levels is an added benefit that fosters a more focused laboratory environment. Moreover, their energy-efficient design helps in reducing operational costs.
Disadvantages: One potential consideration is the initial investment required, as these units demand a higher up-front cost compared to simpler containment solutions. Additionally, the size and weight of these cabinets may pose installation challenges in smaller or less accessible labs.
Product Use in the Field
In practical applications, the Class II A2 Biological Safety Cabinets are vital in medical and research laboratories. They are extensively employed in fields working with infectious agents that require safe handling and containment to protect personnel and ensure the integrity of experiments involving biological materials.
Routine tasks like tissue culture or handling of pathogens in these biosafety cabinets reduce the risk of contamination and exposure, making these pieces of equipment indispensable in facilities dealing with microbiological and biomedical processes.
Recommendations
To maximize the utility and longevity of your Biological Safety Cabinet, it is recommended to conduct regular maintenance and calibration checks. Ensure filters are replaced timely to sustain optimal filtration efficiency, and follow routine cleaning protocols to uphold sterile conditions.
Additionally, training personnel on proper usage and safety procedures will not only enhance the lifespan of the equipment but also foster a safer lab environment. For detailed guidelines or to schedule maintenance services, please consult with one of Kalstein’s expert technicians.
If you are on the lookout for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury to explore our exclusive catalog of laboratory equipment. We manufacture each piece of equipment to a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we give life to science, it’s time to be part of our community. https://kalstein.net/en/product/biological-safety-cabinet-100-exhaust-class-ii-a2-biosafety-cabinet-yr05704-yr05707/.