Product Description
The **YR05915 Clinical Refractometer** is a cutting-edge tool designed to deliver precise and reliable readings for a variety of clinical applications. Engineered with advanced technology, this refractometer ensures accuracy and ease-of-use for professionals in medical settings. The device’s measurement range spans from 0-12g/dl (grams per deciliter), with a specific gravity range of 1.000-1.050sg, and a refractive index from 1.3300RI to 1.3600RI, making it versatile for numerous applications.
With an emphasis on precision, the YR05915 boasts a minimum division of 0.2g/dl, 0.001 SG, and 0.001 RI, coupled with an impressive accuracy of ±0.2g/dl, ±0.001 SG, and ±0.001 RI. This ensures that each reading taken is both dependable and consistent. Moreover, the inclusion of Automatic Temperature Compensation (ATC) from 10-30°C further enhances its reliability by adjusting readings according to ambient temperature changes, making it a practical instrument for everyday use in various environments.
Model | YR05915 |
Description | ATC Clinical 0-12g/dl 1.000-1.050sg 1.3300RI-1.3600RI optical refractometer |
Measurement Range | 0-12g/dl 1.000-1.050sg 1.3300RI-1.3600RI |
Min. Div. | 0.2g/dl 0.001 SG 0.001 RI |
Accuracy | ±0.2g/dl ±0.001 SG ±0.001 RI |
ATC | Yes |
ATC Temp. | 10-30°C |
Material | Pure aluminum |
Market Price
When considering the purchase of a clinical refractometer, one factor to be mindful of is the cost. On the market, refractometers similar to the YR05915 model usually range from approximately 70 USD to 210 USD. This range provides a general idea of what to expect, helping you align your budget with your quality expectations.
The YR05915 stands out not only due to its precision but also for the value it offers at its price point. The combination of advanced features and affordability makes this refractometer a wise investment for any clinical or laboratory setting. Explore potential savings and ensure you’re getting the best price by visiting Kalstein’s official platform to request a quote or use Kalstein Plus for an automated quotation process.
Frequently Asked Questions
What is the scope of the refractometer’s application?
The YR05915 is designed for a wide range of clinical measurements, including blood serum, plasma, and other clinical fluids, providing both versatility and reliability.
How do I ensure accurate readings?
To ensure accuracy, use the refractometer in the recommended temperature range with Automatic Temperature Compensation (ATC) enabled, and regularly calibrate the device according to the manufacturer’s guidelines.
Is the refractometer easy to maintain?
Yes, thanks to its durable aluminum body and user-friendly design, routine maintenance is straightforward and requires minimal effort.
Advantages and Disadvantages
One of the principal advantages of the YR05915 refractometer is its precision. With fine minimum divisions and impressive accuracy, users can trust the device to deliver consistent and exact results. Another benefit is the inclusion of ATC, which ensures reliable readings regardless of environmental temperature fluctuations.
On the downside, users should note that, like any optical instrument, it requires careful handling to prevent damage. Moreover, while the price is accessible, those requiring devices for more specific or advanced applications might need additional features not included in this model.
Product Use in the Field
The **YR05915 Clinical Refractometer** is practically indispensable in laboratory and clinical settings. Its primary use revolves around measuring the concentration of solutions, crucial for diagnostic procedures and various laboratory applications. The ease-of-use and portability of this refractometer make it convenient for fieldwork, allowing professionals to obtain results efficiently when time is of the essence.
For straightforward operation, a few drops of the sample are placed on the prism, and then the user simply looks through the eyepiece or reads the LCD display, depending on the model variation. This simple but effective method provides results swiftly, making it an ideal tool for busy labs and clinical practices.
Recommendations
To maximize the longevity and performance of the YR05915, users are advised to clean the refractometer after each use to prevent residue buildup, which can affect accuracy. Calibration should be performed regularly using distilled water or the manufacturer’s recommended solution to validate the device’s accuracy over time.
Store the refractometer in a protective case when not in use to prevent scratches or exposure to dust and other environmental contaminants. It’s also essential to handle the instrument with care to maintain its precision and functionality. For further inquiries and to obtain the best price offer, reach out through Kalstein’s platform and take advantage of Kalstein Plus automated quotes.
If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each equipment with a high level of excellence. Our intuitive and efficient online shopping channels are designed for your convenience, ensuring the most affordable prices. Don’t hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/clinical-refractometer-yr05915/.