Product Description
The Multifunctional Imager YR06067 and YR06068 are cutting-edge devices designed to meet the highest demands in laboratory imaging. Equipped with cooled CCD cameras, these models provide exceptional quality and precision, with a remarkable physical resolution of 6 Megapixels (2750 x 2200). This enables users to capture highly detailed images crucial for research and analysis.
These imagers are built to accommodate diverse laboratory needs, featuring a pixel density of 16 bits and offering 65,536 gray scales. This ensures superior image depth and clarity. Furthermore, their dynamic range, boasting ≥4.6 OD, enhances the accuracy and versatility for various imaging applications, allowing professionals to work with a broader range of samples.
Temperature regulation is precise with cooling capabilities up to -60℃ below ambient and an additional regulated setting at -30℃. This feature is crucial for maintaining the optimal functionality of the device, reducing noise, and increasing the life span of the camera’s sensors.
The YR06067 is equipped with a sensitive F0.95 scientific lens, while the YR06068 boasts an ultra-sensitive F0.8 lens, providing users with tailored options to meet specific imaging requirements. These lens options ensure that researchers can capture even the faintest signals with ease.
Specification | YR06067 | YR06068 |
---|---|---|
Digital Camera | Cooled CCD Camera | |
Physical Resolution | 6 Megapixels, 2750×2200 | |
Pixel Density and A/D | 16 Bit | |
Grey Scales | 65,536 | |
Dynamic Range | ≥4.6 OD | |
Cooling Temperature | -60℃ below ambient, -30℃ regulated | |
Scientific Lens | F0.95 Lens | Ultra sensitive F0.8 Lens |
Chemiluminescence sample tray | 4 Layer | |
UV Transmission | 302nm-312nm, area: 21x26cm | |
White LED Transmission | Area: 19x26cm | |
Filter Wheel | Five position | |
Filter | Gel Doc Filter | |
UV Protection | UV Protection Shield | |
Image Acquisition Software | No software dongle required, unlimited users, free update | |
Image Analysis Software | No software dongle required, unlimited users, free update |
Market Price
The Multifunctional Imager falls into a price range typical for advanced laboratory imaging equipment, generally between $24,500 and $25,500 USD. This pricing reflects the high-quality build and the advanced functionality these devices offer, making them a worthwhile investment for any research facility.
Frequently Asked Questions
What are the main differences between the YR06067 and YR06068 models?
The primary difference lies in the scientific lens: the YR06067 is equipped with a sensitive F0.95 lens, while the YR06068 has an ultra-sensitive F0.8 lens, facilitating the detection of very faint signals.
Do I need special software to operate these devices?
No, the image acquisition and analysis software provided with these models do not require a dongle, support unlimited users, and include free updates.
Advantages and Disadvantages
The Multifunctional Imager series offers numerous advantages, including high-resolution imaging, advanced cooling mechanisms, and flexible lens options catering to various imaging scenarios. The software’s flexibility adds another layer of convenience, eliminating the need for cumbersome dongles and licensing issues.
However, prospective users should consider the significant investment required, as high-end imaging equipment may not fit all budgets. Additionally, while advanced, these models require proper setup and calibration to maximize their potential, demanding some level of expertise from the users.
Product Use in the Field
These imagers are integral to fields such as biomedical research, chemistry, and materials science, where high-resolution imaging of samples is critical. Their multifunctional design allows for seamless integration with various laboratory workflows, enhancing both efficiency and capability.
In practical scenarios, the imagers enable researchers to conduct precise and comprehensive analyses of samples, revealing details that are otherwise challenging to observe. The flexible filter system and broad range of applications make these models indispensable tools for advanced laboratory research.
Recommendations
To make the most of the Multifunctional Imager, users should regularly calibrate the device for optimal performance. Additionally, it’s recommended to keep the software updated, taking advantage of the free updates to ensure the system’s capabilities are continually enhanced.
Careful handling and consistent maintenance of the cooling system will ensure long-term reliability. For those new to high-resolution imaging equipment, seeking training or consulting with experienced technicians can provide invaluable insights into maximizing device utility.
If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer; we bring science to life. It’s time to become part of our community. https://kalstein.net/en/product/multifunctional-imager-yr06067-yr06068/.