Advanced Technical Insights on Water Purification Systems YR55

Product Description

The YR55 Water Purification System is a state-of-the-art solution designed to meet demanding laboratory needs for pure water. This model provides an efficient output, processing urban tap water under specific conditions: an inlet water pressure range of 0.15-0.5 MPa and temperature between 5°C and 40°C.

Among its standout features, this system boasts a water flow speed of 1.5-2 L/min when equipped with a pressure barrel and offers a machine capacity of 15 L/H. It caters to high-quality output water requirements, offering both RO water and UP water. The RO water achieves a conductivity level of 1-5 μS/cm, complying with ASTM type III water standards, while the UP water is characterized by a resistivity of 18.25 MΩ.cm at 25°C, conforming to ASTM type I water standards, with TOC levels under 3 ppb, particulate matter fewer than 1/ml, and microorganisms below 1 cfu/ml.

Model YR55 YR55-1 YR55-2 YR55-3
Inlet water source Urban tap water, inlet water pressure: 0.15-0.5 MPa, water temperature 5-40°C
Water flow speed 1.5-2 L/min (with pressure barrel)
Machine capacity 15 L/H 15 L/H 15 L/H 15 L/H
Output Water quality RO water: Conductivity 1-5 μS/cm (ASTM type III water)
UP water: resistivity 18.25MΩ.cm@25°C (ASTM type I water)
TOC: <3 ppb, particles (>0.22 um) <1/ml, microorganism <1 cfu/ml
Total organic carbon (TOC) <10 ppb <3 ppb
Pyrogen (endotoxin) N/A < 0.001 Eu/ml N/A < 0.001 Eu/ml
Ribonuclease (RNases) N/A <1pg/ml N/A <1pg/ml
Deoxyribonucleases N/A <5pg/ml N/A <5pg/ml

Market Price

The YR55 Water Purification System is positioned competitively in the market, with prices typically ranging from $8,000 to $8,800. This variance allows different laboratories with varying budgets to access advanced purification technology, ensuring they can maintain the high standards required in scientific environments.

Frequently Asked Questions

What types of water can the YR55 process?

The YR55 is optimized to purify urban tap water with specific conditions regarding pressure and temperature, ensuring robust performance and output quality.

Does the system require regular maintenance?

Yes, regular maintenance is crucial to ensure long-lasting efficiency and output quality of the system. All maintenance schedules are detailed in the user manual provided.

How does the system ensure reduced TOC and microorganism levels?

The system integrates advanced filtration and purification technologies that significantly lower TOC levels and control microbial presence, achieving <0.001 Eu/ml pyrogen production and offering safe, lab-grade water.

Advantages and Disadvantages

Advantages: The YR55 model delivers premium quality water, catering to both type I and type III water requirements. Its high resistivity and low TOC specifications make it ideal for sensitive laboratory applications, ensuring precision in experimental results. Furthermore, the system’s capacity to produce 15 L/H offers substantial output for various laboratory scales.

Disadvantages: Despite its high-performance output, this system requires a stable inlet water source under specific pressure and temperature conditions, which may pose challenges for some environments without adequate setup adjustments.

Product Use in the Field

The YR55 Water Purification System is widely used in laboratory environments where precise water quality is critical. From pharmaceutical labs requiring ultra-pure water for sensitive experiments to educational institutions conducting routine laboratory exercises, the system provides versatile solutions.

Its application extends to the production of reagents used in molecular biology and chemical synthesis, where high purity water reduces contamination risks. Operational simplicity and robust design ensure users can focus on their research without frequent system interruptions.

Recommendations

To maintain optimal performance of the YR55 system, regular filter replacements and timely system checks are essential. It’s advised to keep the system in areas with controlled environmental conditions to minimize the risk of fluctuations that could disrupt water purification processes.

For laboratories with varying water quality needs, calibrating the system’s settings to specific output requirements can enhance efficiency and longevity. Regular training sessions for lab staff on system operation and maintenance can further ensure seamless integration into daily laboratory workflows.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most user-friendly prices. Don’t hesitate any longer; we bring science to life. It’s time to join our community. https://kalstein.net/en/product/water-purification-system-yr55-yr55-3/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]