The Total Organic Carbon (TOC) Analyzer models YR04947 and YR04948 stand out as exceptional tools for precise organic carbon assessment in laboratory environments. With a detection range of 0.001-1.500mg/l (ppm) and a remarkably low detection limit of 1ppb, these analyzers provide high accuracy, with a maximum tolerance of ±5%, ensuring reliable data for critical analysis. Designed for swift operation, the analysis time is as brief as 3 minutes, with a response time of within 10 minutes, streamlining the workflow for researchers and technicians.

These TOC analyzers accommodate a wide range of sample temperatures from 1-95℃, making them versatile for various analytical requirements. They function optimally within an environmental temperature range of 10-40℃, with allowable temperature fluctuations of ±5 ℃/day. Ensuring continuous flow, the sample flow speed is maintained at 3ml/min, while the operating conditions are kept under control with relative humidity levels not exceeding 85%. The repeatability tolerance remains at an impressive ≤3%, and drifting is maintained within ±5%, guaranteeing consistency in results.

Model YR04947 YR04948
Detection range 0.001-1.500mg/l (ppm)
Detection limit 1ppb
Max tolerance ±5%
Analysis time 3 min
Response time within 10 min
Sample temperature 1-95℃
Environment temperature 10-40℃ with temperature change ±5 ℃/d
Sample flow speed 3ml/min
Relative humidity ≤85%
Repeatability tolerance ≤3%
Drifting ±5%
Power Supply AC 220V,50/60Hz or AC 110V
Frequency 50/60Hz
Rated Power 100W
Dimension 440*220*300mm

Market Pricing

The Total Organic Carbon Analyzer models YR04947 and YR04948 are competitively priced within the market segment, typically ranging between $18,800 to $19,500. This pricing tier places them as an attractive option for laboratories seeking precision instrumentation without compromising on budget efficiency. These tools are not only investments in quality but also hold a fair price-to-performance ratio, particularly with the inclusion of advanced features and robust engineering.

Frequently Asked Questions

What is the primary use of the Total Organic Carbon Analyzer?

The TOC Analyzer is primarily used to determine the total amount of organic carbon present in a liquid sample, crucial for water quality assessment and environmental analysis.

What maintenance does the TOC Analyzer require?

Regular maintenance for the TOC Analyzer typically involves cleaning the system to prevent contamination, calibrating the device as needed, and checking for system updates to ensure accurate results.

Is the device compatible with various power supplies?

Yes, the analyzer can operate with power supplies of either AC 220V or AC 110V, making it adaptable for varied electrical standards globally.

Advantages and Disadvantages

Advantages: The YR04947 and YR04948 models boast high precision with a low detection limit, rapid analysis time, and robust construction, making them suitable for diverse applications in scientific research and quality control. The flexibility in sample and environment temperature ranges ensures broad usability.

Disadvantages: A potential downside could be the initial investment cost, which may appear substantial for smaller laboratories, and the need for routine maintenance to sustain optimal performance and precision over time.

Field Usage

The Total Organic Carbon Analyzers find extensive use in environmental monitoring, where the rapid assessment of organic contaminants in water sources is critical. They are equally indispensable in pharmaceutical, chemical, and industrial wastewater applications, providing fast and reliable data necessary for compliance and safety assessments. Their ease of integration into existing laboratory setups enhances their practicality, offering streamlined solutions for technical teams.

In real-world scenarios, these devices enable researchers and technicians to obtain real-time data, supporting informed decision-making and compliance with environmental regulations. Their speed and accuracy ensure they are valuable assets in any analytical toolkit.

Recommendations

Regular calibration and maintenance are recommended to ensure the TOC Analyzer functions at its best. Additionally, operators should be adequately trained in its use to maximize data accuracy and optimization of resources. Prioritize using compatible sample bottles and reagents to maintain the integrity of results. It is also advisable to subscribe to Kalstein Plus for automatic updates and system enhancements.

If you’re looking for a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Don’t hesitate any longer; we bring science to life, it’s time to join our community. https://kalstein.net/en/product/total-organic-carbon-analyzer-yr04947-yr04948/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]