Description of the Product
Kalstein’s Tumor Test Markers, models YRA385 to YRA391, represent a cutting-edge development in oncology diagnostics. Engineered to quantify tumor-specific markers accurately, these models have been tailored to detect a range of parameters integral to cancer diagnosis and management, including AFP, CEA, CA125, CA15-3, CA19-9, f-PSA, and t-PSA. Each model operates using Chemiluminescent Immunoassay (CLIA), a preferred method for its sensitivity and specificity in clinical settings.
These markers, available in packaging specifications of 50T/BOX, 100T/BOX, and 24T/BOX, make flexibility and scalability in the laboratory possible. The platform employed is Alkaline Phosphatase (AP), ensuring reliable enzyme-based detection. With optimal storage at 2-8°C and rigorous calibration options set at 2/6 points, these products adhere to international standards, backed by CE, ISO13485, and FSC certifications.
Model | YRA385 | YRA386 | YRA387 | YRA388 | YRA389 | YRA390 | YRA391 |
Tested Parameter | AFP | CEA | CA125 | CA15-3 | CA19-9 | f-PSA | t-PSA |
Analysis Mode | CLIA | ||||||
Package Specification | 50T/BOX, 100T/BOX, 24T/BOX | ||||||
Platform | AP(Alkaline Phosphatase) | ||||||
Storage | 2-8°C | ||||||
Calibration | 2/6 Points | ||||||
Certification | CE, ISO13485, FSC |
Market Price
The pricing for tumor test markers varies significantly depending on the technology, packaging specifications, and whether they come as a single-use test or part of a larger analytical system. Kalstein offers competitive pricing, with an emphasis on providing cost-effective solutions without compromising on quality. Potential buyers are encouraged to explore the Kalstein Plus platform for dynamic pricing options and to request a quote tailored to their specific needs.
Frequently Asked Questions
What are the main advantages of using CLIA for tumor marker testing?
CLIA, or Chemiluminescent Immunoassay, offers high sensitivity and specificity, making it ideal for detecting low concentrations of tumor markers in the blood. This ensures early detection and more accurate monitoring of cancer progression.
How should the tumor test markers be stored?
The tumor test markers must be stored at a temperature range of 2-8°C. This ensures the stability and integrity of the test components, providing reliable results when used.
Are there volume discounts available for bulk purchases?
Yes, Kalstein offers volume discounts for bulk purchases. Customers are advised to contact the sales team to discuss their specific needs and volume pricing options.
Advantages and Disadvantages
One of the primary advantages of Kalstein’s Tumor Test Markers is their precision and adaptability to various cancer markers, allowing for comprehensive cancer monitoring. The use of CLIA technology ensures high sensitivity, while the CE and ISO certifications attest to their global standard compliance. However, one possible disadvantage is that these tests require specific storage conditions (2-8°C), which may present a challenge for facilities without adequate refrigeration solutions.
Another advantage lies in their flexible packaging options, which cater to different laboratory needs. On the downside, purchasing and managing several different models for various markers might require more complex inventory management in busy laboratories.
Use of the Product in the Field
In clinical settings, Kalstein’s Tumor Test Markers are utilized by medical professionals to assist in the early detection and ongoing monitoring of cancer. After a blood sample is taken from a patient, the specific tumor markers of interest are measured using the CLIA method. This aids doctors in diagnosing the presence and possibly even the stage of cancer, guiding further treatment decisions.
These markers also play a crucial role in follow-up scenarios, where they are used to assess the effectiveness of ongoing treatment regimens or to check for cancer recurrence post-treatment. Thus, they are a vital part of personalized cancer care strategies.
Recommendations
To maximize the benefits of using Kalstein Tumor Test Markers, users must adhere to the recommended storage guidelines to maintain test integrity. Regular calibration checks should be performed to ensure accurate results, particularly if the systems are being used in high-volume scenarios. By leveraging the Kalstein Plus platform, users can also take advantage of automatic reminder systems for reordering and maintenance scheduling, ensuring that the tests are always ready for use when needed without risk of stockouts or degradation due to improper storage.
If you’re looking for a merge of innovation and quality, you’ve come to the right place. At Kalstein, we offer the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchasing channels are designed for your comfort, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life. It’s time to be part of our community. https://kalstein.net/en/product/tumor-test-marker-yra385-yra391/.