The Portable Veterinary Capnograph and SpO2 Monitor models YR06108 – YR06109 represent a significant leap in the monitoring of animal vital signs. With a precise range of measurement variables such as SpO2 (0-100%), Pulse Rate (36-254bpm), EtCO2 (0-150mmHg) and Respiratory Rate (3-120bpm), these devices are true masterpieces of technology and precision.
Each model has its own set of unique features designed to maximize the accuracy of measurements and ensure reliable results at all times. The electrical safety of the devices is also exceptional, with input and output adapters, as well as rechargeable lithium batteries that can provide up to 10 hours of uninterrupted operation.
Improving Accuracy with Robust Measurement Tools
The accuracy of the SpO2 measurement of these two models varies in a small range of ±2% (70-100%), ensuring the reliability of the results. As for the pulse rate, the accuracy is impressive, with a deviation of only ±2 or ±2bpm. https://kalstein.net/en/product/handheld-veterinary-capnograph-spo2-monitor-yr06108-yr06109/
The accuracy of the EtCO2 measurement is maintained at ±5% of the reading, offering constant and reliable tracking of the concentration of carbon dioxide in animal breathing. The respiratory rate also has great accuracy, with a variation of only ±1 breath.
Standard Settings and Customized Options
Each of these devices comes with a standard configuration that includes the main unit and elements such as the sample line, nasal sample line, CO2 adapter, and SpO2 sensor, among others. This configuration ensures a high level of flexibility and usability for veterinary professionals.
In addition, each model offers additional configuration options to adapt to the specific needs of different veterinary practices. The YR06109 models, for example, offer a Side Stream CO2 Sensor as an additional option.
Innovation and Energy Efficiency
The use of rechargeable lithium batteries in these devices ensures up to 10 hours of continuous operation, allowing veterinary professionals to use them in the field without the need for a continuous power source. The output current intensity is up to 2A with a voltage of 12V, and the entire device has a charging time of 4 hours. If you want to know the catalogue of high-end products that KALSTEIN have for you visit us https://kalstein.net/en/
Wide Application in Veterinary Medicine
These devices are essential in various veterinary procedures, such as in anesthesia monitoring, during surgeries and evaluations of respiratory function, in both small and large animals. The accurate measurement of pulse rate and respiratory rate is particularly peculiar in cases of veterinary emergencies.
They are also used in the management of chronic diseases, such as heart and lung problems, where constant and accurate tracking of animal vital functions is crucial. The YR06109 model, in particular, is essential for monitoring CO2 levels, especially useful in major surgeries where animal intubation is required.
Medical Applications of the Equipment
- Monitoring anesthesia in surgical procedures.
- Evaluation and monitoring of respiratory function.
- Surveillance of pulse rate in emergency situations.
- Monitoring of chronic diseases such as heart and lung problems.
- Measurement and tracking of carbon dioxide levels.