The Operating Lamps YR02106 and YR02112 represent the pinnacle of innovation in surgical lighting. Designed to provide optimal illumination during critical medical procedures, these lamps offer exceptional features that ensure a safe and efficient surgical environment.
The technical specifications of these models stand out for their high lighting capacity and precision in color rendering. The YR02106 model provides 160,000 lux illumination at a distance of 1 meter, while the YR02112 achieves the same light intensity. Both lamps offer adjustable color temperature ranging from 3500K to 6700K, allowing surgeons to adjust the light according to their specific needs. Additionally, they boast a bulb life of up to 50,000 hours, ensuring long-lasting and reliable performance.
Technical Specifications |
YR02106 |
YR02112 |
Illumination at 1m (lux) |
160000 |
160000 |
Illumination at 1m in Endo model (lux) |
15000 |
– |
Light field diameter D10 mm |
180±40 |
180-300 |
D50 mm |
110±35 |
180-300 |
Illumination depth L1+L2 mm |
150 |
1000 |
Color rendering index (Ra) |
100≥Ra≥85 |
≥97 |
Red color index R9 |
R9≥97 |
≥97 |
Optional color temperature (K) |
6700K ≥Tc≥3500k |
6700K ≥Tc≥3000k |
Bulb life (hours) |
50000h |
50000h |
Heat/light ratio (mW/m²lx) |
<6 |
– |
Power supply |
110-240V |
AC110-240V 50/60Hz |
Input power (VA) |
150W |
150W |
Ceiling height for installation (cm) |
270-320 cm |
260 cm |
These lamps not only guarantee superior illumination but are also designed with an ergonomic focus, ensuring hassle-free installation and operation.
Market Price
The price of operating lamps such as the YR02106 and YR02112 can vary depending on suppliers and additional specifications. Generally, the price range in the market is between $3000 and $8000 USD. This price reflects the advanced technology and durability of these units, ensuring excellent value for money.
Frequently Asked Questions
What is the lifespan of the YR02106 and YR02112 operating lamps?
The bulbs of both lamps have an estimated lifespan of 50,000 hours, ensuring a long period of use before needing replacements.
Can the color temperature and light intensity be adjusted?
Yes, both lamps allow adjustments in color temperature between 3500K and 6700K and in light intensity to suit the specific needs of the surgical procedure.
What is the minimum ceiling height required for installation?
For the YR02106, the minimum ceiling height required is 270 cm, while for the YR02112 it is 260 cm.
Advantages and Disadvantages
Advantages
-
High light intensity: Provides illumination up to 160,000 lux, ensuring optimal visibility during surgeries.
-
Superior color rendering: With a color rendering index (Ra) of up to 97, it allows better differentiation of tissues and anatomical structures.
-
Long lifespan: The bulbs with an average life of 50,000 hours reduce the frequency of replacements and associated costs.
-
Adjustable color temperature: The ability to adjust the color temperature allows the light to be adapted to different surgical needs.
Disadvantages
-
Initial cost: The initial investment may be high compared to lower quality models.
-
Requires professional installation: Installation of these lamps may require specialized technical personnel due to their specifications.
Product Use in the Field
In real surgical scenarios, the YR02106 and YR02112 Operating Lamps stand out for their ability to provide constant and high-quality lighting, crucial for procedures that require extreme precision. Surgeons can benefit from the depth of illumination these models offer, allowing clear visualization even in deep cavities. Additionally, the high color rendering ensures that tissue colors are perceived accurately, facilitating the differentiation of critical structures during surgery.
Recommendations
To maximize the use and lifespan of the YR02106 and YR02112 Operating Lamps, it is advisable to follow these tips:
-
Regular maintenance: Conduct periodic inspections and cleanings to avoid the accumulation of dust and residues that could affect light performance.
-
Staff training: Ensure that medical staff are well trained in the use and adjustments of the lamps to take advantage of all their functionalities.
-
Proper installation: Hire specialized technicians for the correct and safe installation of the lamps, ensuring all technical specifications are met.
Call to Action
If you are looking to improve the quality of lighting in your operating room, the YR02106 and YR02112 Operating Lamps are the ideal choice.
With their high light intensity, superior color rendering, and long lifespan, these models represent a safe investment for any surgical center. Request a quote or generate an automatic quote through the Kalstein Plus platform and discover how these lamps can transform your surgical procedures.
Are you yearning for top-tier medical equipment, ready to enhance the efficiency of your laboratory? Visit https://kalstein.net/en/product/operation-lamp-yr02106/ to explore our high-end catalog, packed with the best finds at the most competitive prices. Excellence marks our brand, we innovate and manufacture high-precision equipment, both reliable and durable to meet your needs. Why wait? Make your quick and secure online purchase, take the leap towards the future of medical technology today. https://kalstein.net/en/