Turbocharged Veterinary Anesthesia Ventilator YR06104: Innovation in Respiratory Support for Surgical Procedures

In veterinary medicine, precise and efficient respiratory support is essential to ensure the well-being of animals during complex surgical procedures. The Turbocharged Veterinary Anesthesia Ventilator YR06104 from Kalstein is a tool designed to provide total control in the administration of anesthesia, enhancing safety and outcomes in veterinary patients. This device, with its advanced technology and robust design, is adapted to the demands of modern veterinary clinics and surgical centers, offering a wide range of adjustable parameters that ensure full customization according to the patient’s needs.

The YR06104 is designed to handle a wide spectrum of patients, from small animals to larger species, thanks to its ability to adjust the tidal volume (TV) from 20 ml to 1500 ml and its respiratory rate from 1 to 150 breaths per minute. With innovative functions like the adjustable inhalation to exhalation ratio, inspiratory pressure, and pressure support, this ventilator ensures precise control of the respiratory cycle. It also integrates advanced monitoring technology, such as real-time waveform visualization for Paw-T, Flow-T, and V_T, allowing veterinarians to visualize and adjust respiratory parameters instantly.

Technical Specifications:

Model YR06104
Tidal volume (TV) 20-1500ml
Breathing rate (Freq) 1-150bpm
Spontaneous breathing rate (Freq_Spont) 0-150bpm
Ratio of inhalation and exhalation (I:E) 9.9:1-1:9 adjustable
Hold time 0-50%
Flow trigger sensitivity (F_Tring) 0.5-20L/min, OFF
Pressure Trigger Sensitivity (P_Tring) -1-20cmH2O, OFF
End-expiratory pressure 3-20cmH2O, OFF
SIMV frequency (Fre_SIMV) 2-60bpm
Inspiratory time (T_Insp) 0.1-12s
Pressure support (PS) 0-60cmH2O
Inspiratory pressure (T_Insp) 0-60cmH2O
Tidal volume of expiratory 0-2500ml
Tidal volume of inspiratory 0-2500ml
Minute Ventilation (MV) Display range: 0-99L/min
Use range: 0-25L/min
Spontaneous minute ventilation (MV_Spont) Display range: 0-99L/min
Use range: 0-25L/min
Peak pressure (Ppeak) 0-80cmH2O
Platform pressure (Pplat) 0-80cmH2O
Mean pressure (Pmean) 0-80cmH2O
Inhaled oxygen concentration (FiO2) 15-100%
End-expiratory pressure (PEEP) 0-20cmH2O
Driving gas pressure (Press_Drive) 0-900kpa
Paw-T waveform Pressure monitoring range: 0~120cmH2O;
X-axis: 0~10s
Flow-T waveform Y-axis:-1800~180L/min
X-axis: 0~10s
V_T waveform Z-axis:0~2000L/min
X-axis:0~10s

These robust specifications ensure that the YR06104 is an ideal solution for a variety of veterinary surgical procedures, where meticulous control of ventilation is required. Additionally, its intuitive interface and real-time monitoring enable the veterinary team to easily adjust parameters to optimize surgical outcomes.

Market Price

The price of the Turbocharged Veterinary Anesthesia Ventilator YR06104 can vary depending on the distributor and additional configurations required. Typically, ventilators in this high-tech veterinary category range from $5000 to $10000 USD. However, at Kalstein, we pride ourselves on offering competitive prices that meet the needs of our clients. To get an exact and personalized quote, we invite you to use our Kalstein Plus platform, where you can generate an automatic quote quickly and easily.

Frequently Asked Questions

Is the YR06104 suitable for animals of different sizes?

Yes, this ventilator is designed to handle a wide range of species, from small animals to larger ones, thanks to its adjustable tidal volume and respiratory rate.

Does the device require specialized maintenance?

The ventilator is built for long-term use and easy maintenance. Kalstein offers technical support and replacement parts to ensure its long-term functionality.

Can I monitor all parameters in real time?

Yes, the ventilator displays critical values like tidal volume, inspiratory pressure, and respiratory waveforms in real time, allowing precise supervision.

How can I adjust the ratio?

The ventilator allows adjustment of the inhalation to exhalation ratio from 9.9:1 to 1:9, providing flexibility to suit various surgical needs.

Can this ventilator be integrated with other equipment?

The YR06104 is designed for seamless integration with other monitoring devices in a clinical setting, facilitating comprehensive patient control.

Does Kalstein offer a warranty for this product?

Yes, all our equipment comes with a full warranty that covers potential manufacturing defects. We also offer ongoing technical support.

Pros and Cons

Pros

Cons

Highly versatile, ideal for a variety of animal species and sizes.

May require a significant initial investment.

Easy-to-read display with real-time monitoring of respiratory parameters.

Proper training is needed to fully utilize its features.

Wide range of adjustments, including tidal volume, respiratory rate, and pressure settings.

Not all veterinary hospitals may have the resources to acquire equipment of this level.

Oxygen control adjustable up to 100% for maximum customization.

Technical maintenance may be required to ensure optimal performance.

Robust and durable design, suitable for high-demand clinics.

Requires a constant supply of gas for operation.

Intuitive interface, easy for clinical staff to use.

 

Field Use of the Product

The Turbocharged Veterinary Anesthesia Ventilator YR06104 has proven to be an essential tool in veterinary clinics and hospitals, especially during complex surgical procedures. Its ability to precisely adjust respiratory parameters allows veterinarians to ensure that patients receive the appropriate ventilatory support based on their condition. In the field, it is used in procedures ranging from routine surgeries to more advanced interventions, where maintaining respiratory control under general anesthesia is crucial.

Additionally, this ventilator has been particularly useful in managing respiratory emergencies in critical patients, providing immediate support with customized adjustments as needed. Veterinarians who have used it highlight its ability to deliver smooth and controlled ventilation, improving clinical outcomes and reducing risks associated with anesthesia.

Recommendations

To maximize the efficiency of the Turbocharged Veterinary Anesthesia Ventilator YR06104, it is recommended that clinical staff receive proper training on its use and configuration. This will ensure that all the advanced features of the equipment, such as waveform monitoring and respiratory cycle customization, are fully utilized. Regular maintenance, following the manufacturer’s guidelines, is also recommended to ensure optimal performance over time.

If you are considering this ventilator for your veterinary clinic, feel free to request a demonstration or quote through Kalstein Plus. Our support team is available to answer any questions and guide you through the process of acquiring this essential equipment.

If you are looking for a blend of innovation and quality, you have come to the right place. At https://kalstein.net/en/product/turbo-driven-veterinary-anesthesia-ventilator-yr06104/, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our online shopping channels, intuitive and agile, are designed for your convenience, ensuring the most user-friendly prices. Don’t hesitate any longer, we bring science to life; it’s time to be part of our community. https://kalstein.net/en/

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]