Product Description
The YR05726 Horizontal Laminar Flow Cabinet is designed to provide unparalleled cleanliness and efficiency in various laboratory settings. This cutting-edge equipment ensures a Class 100 cleanliness level at ≥0.5μM according to the US Federal Standard 209E. With a low number of colonies, ≤0.5pcs/dish·hour on a Φ90mm culture plate, it offers an optimal environment for sensitive procedures.
Engineered for reliability, the YR05726 operates with an average wind speed of 0.25~0.45m/s and maintains low noise levels of ≤62dB(A). Its structural integrity is enhanced by minimal vibration (≤5μM) in all directions (x, y, z), ensuring stable operating conditions. The cabinet is equipped with sufficient illuminance (≥300Lx) and is powered by an AC single phase 220V/50Hz supply, with a maximum power consumption of only 100W.
Its work area dimensions of 700×410×580 and external dimensions of 860×590×1600 provide ample space for laboratory tasks. The high-efficiency filter specifications measure 680×565×50, complemented by a lighting system that includes a 12W and a 20W lamp. With a weight of 80Kg, the unit promises durability and ease of maintenance.
Model | YR05726 |
Cleanliness Level | Class 100@≥0.5μM (US Federal 209E) |
Number of Colonies | ≤0.5pcs/dish·hour (Φ90mm culture plate) |
Average Wind Speed | 0.25~0.45m/s |
Noise | ≤62dB(A) |
Vibration Half Peak | ≤5μM(x、y、z direction) |
Illuminance | ≥300Lx |
Power Supply | AC single phase 220V/50Hz |
Maximum Power | 100W |
Weight | 80Kg |
Work Area Size W1×D1×H1 |
700×410×580 860×590×1600 |
Dimensions | Single/Single |
High Efficiency Filter Specification and Quantity | 680×565×50 |
Specification and Quantity of Fluorescent Lamp/Ultraviolet Lamp | 12W×1 20W×1 |
Market Price
The YR05726 Horizontal Air Laminar Flow Cabinet is a sophisticated and high-quality piece of equipment that sees a price range in the market generally between $1000 to $1800 USD. This range reflects its exceptional technical capabilities and reliability, making it a prudent investment for any laboratory focused on maintaining superior working conditions. Please note that prices can fluctuate based on additional support options or custom features.
Frequently Asked Questions
What is the primary use of the YR05726 Laminar Flow Cabinet?
The YR05726 is primarily used to maintain a sterile environment by filtering air and minimizing contamination in laboratory settings. It is essential for operations requiring high cleanliness levels, such as microbiology or medical research.
Can the cabinet’s noise levels affect laboratory work?
With noise levels capped at ≤62dB(A), the YR05726 operates quietly, ensuring minimal disruption, and contributing to a conducive laboratory environment.
Is the power consumption high?
The cabinet’s energy efficiency is noteworthy with a maximum power requirement of only 100W, making it both cost-effective and environmentally friendly.
Advantages and Disadvantages
The YR05726 Horizontal Laminar Flow Cabinet stands out for its precision and reliability. **Advantages** include its impressive cleanliness level, energy efficiency, and the ability to provide consistent flow speed and low noise operation. The design ensures stable operations with minimal vibrations, making it suitable for delicate tasks.
**Disadvantages** might include the initial investment cost and the need for routine maintenance to ensure optimal filter performance. Additionally, while the cabinet is relatively lightweight for its class, its size may require sufficient space allocation within smaller laboratories.
Field Use of the Product
In practical scenarios, the YR05726 is deployed in a wide range of laboratory applications. Its design allows for seamless integration into environments demanding stringent control measures, such as in pharmaceutical or biotechnology labs, where maintaining a contaminant-free area is critical. Healthcare settings may also use this cabinet for clinical research and drug preparation.
The ease of use and reliable performance ensure that even in high-demand conditions, the cabinet maintains its specifications, providing users peace of mind and confidence in their outcomes.
Recommendations
For optimal performance, regularly inspect and replace the high-efficiency filters as required to maintain the intended cleanliness standards. Users should also ensure proper installation in a space that supports its dimensions and allows for regular maintenance checks.
Maximize the lifespan and efficiency of the YR05726 by adhering to manufacturer-recommended procedures. Training staff on the proper use and routine care practices will significantly enhance the equipment’s durability and effectiveness.
If you are in search of a fusion of innovation and quality, you have come to the right place. At Kalstein, we invite you to explore our exclusive range of laboratory equipment. Every piece is manufactured with a commitment to excellence. Our intuitive and efficient online purchasing channels ensure competitive pricing for your convenience. Don’t hesitate, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/class-100-horizontal-air-laminar-flow-cabinet-yr05726/.