Product Description
The Hospital Ultra-Low Temperature Deep Freezer YR05111 stands as a pinnacle in laboratory refrigeration technology, designed to meet the rigorous demands for precise freezing conditions. This sophisticated equipment offers a sprawling capacity of 838 liters, allowing for the storage of vast quantities of critical samples, making it an invaluable asset in medical and scientific settings.
Constructed with high-quality stainless steel shelves and equipped with a durable color-sprayed steel exterior, this freezer promises longevity and resilience in demanding environments. The YR05111 operates with a microprocessor-controlled temperature system, ensuring precise temperature regulation ranging from -40°C to -86°C, providing exceptional preservation capabilities for sensitive materials.
The technical brilliance of this equipment is underscored by its use of dual SECOP compressors and a PTC sensor, promising efficient and consistent cooling. The YR05111 employs a direct cooling system, complemented by manual defrosting and a mixed-gas refrigerant, thereby optimizing energy efficacy. With a power consumption of 18.8 kWh/24h and operating noise levels at 55 dB, it maintains a balance between performance and operational economy.
Model | YR05111 |
Specifications | |
Shelf/drawer QTY | Stainless steel shelf/3 |
Cooling | Direct cooling |
Defrost | Manual |
Refrigerant | Mixed-gas |
Power Consumption(kWh/24h) | 18.8 |
Noise(db) | 55 |
Ambient temperature(℃) | 10~32℃ |
Temperature range(℃) | -40~-86℃ |
Cooling system | |
Compressor brand/QTY | SECOP/2 |
Sensor | PTC |
Temperature controller | Microprocessor |
Display | Digital display |
Power | |
Voltage/frequency(V/Hz) | 220/50Hz |
Power(W) | 1700W |
Current(A) | 9.8A |
Material | |
Inside material | Stainless steel |
Outside material | Color sprayed steel |
Insulation | PURF |
Size | |
Capacity(L/cu.ft) | 838/29.59 |
NT./GT.(kg) | 344/430 |
Exterior size(W*D*H)(mm) | 1175*1075*1990 |
Interior size(W*D*H)(mm) | 894*718*1310 |
Package size(W*D*H)(mm) | 1270*1100*2185 |
CBM | 03.05 |
20GP/40GP/40HQ | 8/18/18 |
Frozen Racks | |
Racks | 24(5X5) |
Boxes (2 Inches) | 600 |
Samples(2ml) | 60000 |
Alarm | |
High/low temperature | Y |
Power failure | Y |
Abnormal voltage | Y |
Sensor error | Y |
Filter screen check | Y |
Thermostat failure | Y |
Low battery | Y |
Condenser clean | Y |
High ambient temperature | Y |
Door ajar | Y |
Power failure backup system(alarm) | 72h |
Accessories | |
Castor | Y |
Inside door | 2 |
Test hole QTY/diameter | 1/25MM |
USB port | Y |
Chart recorder | / |
Data logger | Optional |
Remote alarm port | Y |
Optional | |
CO2 back up system | Optional |
LN2 back up system | Optional |
Other | |
Certification | ISO.CE |
Market Price
The Hospital Ultra-Low Temperature Deep Freezer YR05111 is competitively placed in the market, reflecting its advanced features and robust design. Typically, ultra-low temperature freezers range from $10,000 to $25,000 depending on the specifications and additional functionalities. The YR05111 can be expected to align within this bracket, offering superior technology justifying its cost. For the latest pricing and offers, consider exploring direct purchase options through suppliers or request a quote via the Kalstein platform.
Frequently Asked Questions
What type of refrigerant does the YR05111 use?
The YR05111 uses a mixed-gas refrigerant, which enhances its cooling efficiency and environmental sustainability.
What is the power consumption of this unit?
This model consumes 18.8 kWh per 24 hours, making it an energy-efficient choice for sustained high-performance cooling.
Is the freezer suitable for long-term storage?
Yes, with a temperature range of -40°C to -86°C and substantial capacity, it is ideal for the long-term storage of sensitive samples.
Advantages and Disadvantages
Advantages: The YR05111 excels in energy efficiency, reliability, and robust construction. Its dual compressors ensure uniform cooling, while the digital display and microprocessor controller provide precise temperature control. The extensive alarm system enhances safety, reducing the risk of sample loss.
Disadvantages: One potential drawback is the requirement for manual defrosting, which can be time-consuming and somewhat labor-intensive. Additionally, initial investment costs may be high for some facilities.
Field Use of the Product
In practical settings, the YR05111 is invaluable for institutions requiring rigorous temperature control for sensitive biological products, pharmaceuticals, and specimens. It is a staple in hospitals for the storage of blood products and in laboratories for preserving specimen integrity over extended periods.
The functionality of the YR05111 extends to research institutions where unyielding conditions are necessary to support experimental integrity, making it a trusted choice for safeguarding invaluable samples.
Recommendations
To maximize the efficacy of the YR05111, regularly monitor the internal temperature and activate alarms promptly to mitigate any risks. Engage in periodic maintenance and inspections to ensure the cooling system’s longevity. Additionally, familiarize staff with the operational manual to leverage all features effectively. For optimal results in ambient conditions, place the unit in a temperature-controlled environment.
Contact Kalstein for precise pricing and customization based on your facility’s unique requirements and take advantage of their streamlined Kalstein Plus service for an easy quotation process.
If you are looking for a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/hospital-ultra-low-temperature-deep-freezer-direct-cooling-yr05111/.