Product Description
The Biological Safety Cabinet YR06205 represents the pinnacle of safety and precision in laboratory environments. Designed according to the stringent international standard ISO14644.1 CLASS 5, it ensures that your workspace adheres to global benchmarks for cleanliness and safety. With an inflow velocity of 0.56 m/s and a downflow velocity of 0.35 m/s with a precision of ±0.015 m/s, this cabinet provides a controlled environment that maintains sterility and reduces contamination risks.
Noise is an often overlooked nuisance in laboratory settings but not with the YR06205 model. The cabinet operates at a noise level of ≤65 dB, ensuring that your work environment remains quiet. The advanced HEPA filter with an efficiency of 99.995% ensures superior air filtration, protecting both samples and personnel.
Model | YR06205 | |||
Clean rating | International standard ISO14644.1 CLASS 5(US209E,CLASS 100) | |||
Inflow velocity | 0.56m/s | |||
Down flow velocity | 0.35m/s | |||
Down flow velocity precision | ±0.015m/s | |||
Noise level(dB) | ≤65 | |||
Vibration | ≤3μm(X、Y、Z direction) | |||
HEPA | efficiency 99.995% | |||
Light intensity(LX) | ≥650 | |||
Pressure difference range (Pa) | 0~500 | |||
Operate environment | environment temp.10-30℃,relative humidity under 70%, no obvious vibration and dust | |||
External dimensions(H*W*D) (mm) | 2120×1035×740 | |||
Dimension of working zone(H*W*D) (mm) | 670×965×560 | |||
Power supply | Single-phase voltage source AC220V/50HZ | |||
Power(W) | 300 |
Market Price
The Biological Safety Cabinet YR06205 is a premium piece of laboratory equipment, valued for its efficiency and safety-focused design. On average, the market price for this category of safety cabinets ranges from approximately 8,500 USD to 9,350 USD, providing an array of high-end features for laboratory settings invested in superior safety standards. This price bracket reflects the cabinet’s advanced technology and rigorous safety features, making it an intelligent choice for both budding and established laboratories.
Frequently Asked Questions
What type of maintenance does the Biological Safety Cabinet YR06205 require?
Regular maintenance involves ensuring that the HEPA filters are replaced annually or if a significant clog is detected. It’s also important to clean the internal surfaces with appropriate non-corrosive disinfectants to maintain sterility.
Is any special installation required for the YR06205 model?
No specific installation procedures are required beyond having a stable, flat surface with access to a single-phase voltage source AC220V/50HZ power supply.
How long can the Biological Safety Cabinet YR06205 operate continuously?
The cabinet is designed for extended continuous usage, up to 24 hours, given appropriate periodic maintenance and environmental conditions are observed.
Advantages and Disadvantages
Advantages: The YR06205 model stands out due to its high efficiency HEPA filter which offers a filtration efficiency of 99.995%. It also maintains a quiet operational noise level, which is essential for a conducive laboratory atmosphere. Additionally, the precision in airflow control ensures optimal protection against contamination.
Disadvantages: The cabinet’s initial investment might be high for smaller labs. Additionally, the model requires strict adherence to maintenance schedules to ensure longevity and optimal performance.
Field Usage
The Biological Safety Cabinet YR06205 is commonly employed in research institutions, clinics, and universities where the containment of pathogens is critical. It offers a reliable shield for technicians working with infectious agents, providing both personal and product protection within its sterile work zone.
In practice, the cabinet allows for simultaneous protection of experiment integrity and user safety, especially critical in microbiology and genetic research applications. Due to its well-engineered features, the YR06205 is a vital tool in any lab focused on maintaining high safety standards.
Recommendations
To maximize the efficiency of the YR06205 Biological Safety Cabinet, ensure that the laboratory environment falls within the optimal temperature and humidity range specified (10-30℃, under 70% humidity). Regularly clean and inspect the cabinet to preempt any issues that might arise from contaminants or equipment wear.
Consider enrolling in Kalstein Plus for automated quotation options and ease of purchase. The platform is designed to simplify procurement for frequent lab equipment acquisitions.
If you are seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece with a level of excellence. Our online shopping channels, intuitive and efficient, are designed for your convenience, ensuring the most friendly prices. Don’t hesitate, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/biological-safety-cabinet-yr06205/.