Product Description
The Multi-Parameter Patient Monitor YR02177 is a state-of-the-art device designed to provide comprehensive monitoring of a patient’s vital signs. Engineered with precision, this monitor integrates the latest technology to ensure accurate and reliable readings. Its ECG functionality supports both 5 leads (RA, LA, LL, RL, V) and 3 leads (RA, LA, LL) configurations, ensuring adaptable monitoring for diverse patient needs. The connection methods include I, II, III, AVR, AVL, AVF, and V, offering robust compatibility with various clinical requirements.
With a broad HR range of 15-300 bpm for adults and up to 350 bpm for neonatal and pediatric patients, the YR02177 caters to a wide array of clinical situations. The ECG accuracy stands at ±1% or ±1 bpm, ensuring high fidelity in cardiac monitoring. Additionally, its differential input impedance is ≥5MΩ, underscoring its capability in handling sensitive medical data. The device also features substantial respiratory monitoring with impedance ranging from 0.3~3.0 MΩ and comprehensive alarm systems for immediate alerts.
Model | YR02177 | |
ECG | Lead mode | 5 Leads(RA,LA,LL,RL,V) / 3 Leads (RA,LA,LL) |
Connection method | I, II, III, AVR, AVL, AVF, V | |
Waveform | 1ch | |
Gain | x250, x500, x1000, x2000 | |
HR Range | Adult: 15~300bpm, Neo/Ped: 15~350bpm | |
Accuracy | ±1% or ±1bpm | |
Resolution | 1bpm | |
Sensitivity | >200(uVp-p) | |
Differential input impedance | ≥5MΩ | |
ST segment Monitoring Range | ||
Measure Range | -2.0~+2.0mV | |
Measure Accuracy | -0.8mV~+0.8mV | |
Heart Rate Sensitivity | >200UVp-p | |
Respiration | Method | Impedance between R-F(RA-LL) |
Differential Input Impedance | >2.5MΩ | |
Measuring Impedance Range | 0.3~3.0 MΩ | |
Base line Impedance Range | 200~4000Ω | |
Bandwidth | 0.1~2.5Hz | |
Respiration Rate | Adult: 2~120BrPM, Neo/Ped: 0~150BrPM | |
Resolution | 1 BrPM | |
Accuracy | ±2 BrPM | |
Alarm | 10~40S | |
NIBP | Method | Oscillometric |
Mode | Manual/Auto/STAT | |
Measuring Interval in AUTO Mode | 1,2,3,4,5,10,15,30,60,90,120,180,240,480(Min) | |
Measuring Period in STAT Mode | 5 Min | |
Pulse Rate Range | 40~240bpm | |
Alarm Type | SYS, DIA, MEAN | |
Pressure Resolution | 1mmHg | |
Accuracy | Maximum Mean error: 5mmHg | |
Maximum Standard deviation | 8mmHg | |
SPO2 | Display | Number of SPO2, waveform of capacity, Pulse |
Measuring range | 0~100% | |
Resolution | 1% | |
Accuracy | 70~100% (±2%) | |
Alarm system | Audio-video alarm | |
Pulse rate range | 0~300bpm | |
TEMP | Channel | 2 |
Measuring and Alarm Range | 0~50ºC | |
Resolution | 0.1ºC | |
Accuracy | 0.1ºC | |
Updating interval | about 1 Second. | |
Average Time Constant | <10 Second. |
Market Price
The Multi-Parameter Patient Monitor YR02177 is competitively priced within the medical equipment market. With technological advancements and increased demand for precise patient monitoring, the price range for this device generally spans between approximately $4600 to $5400 USD. This positioning ensures that healthcare facilities can leverage cutting-edge technology without exceeding budgetary constraints. By investing in the YR02177, medical institutions gain access to a robust monitoring solution that promises reliability and efficiency at a fair market value.
Frequently Asked Questions
What does the Multi-Parameter Patient Monitor YR02177 measure?
The YR02177 is equipped to monitor various physiological parameters such as ECG, heart rate, respiration, NIBP, SPO2, and temperature, offering a comprehensive insight into a patient’s health status.
Is the YR02177 suitable for pediatric monitoring?
Yes, the monitor has been designed to cater to both adult and pediatric patients. Its HR range and respiration parameters are adaptable for neonatal and pediatric care.
How easy is it to operate the YR02177?
The device is user-friendly with intuitive controls and an interface designed for ease of operation, ensuring minimal training requirements for medical staff.
Advantages and Disadvantages
Advantages: The YR02177 offers multi-parameter monitoring capabilities which allow for comprehensive patient observation and quick response to physiological changes. Its audio-video alarm system is crucial for alerting healthcare providers of critical condition shifts. The robust specifications ensure high accuracy and sensitivity, vital for maintaining patient safety.
Disadvantages: While the monitor offers numerous advanced features, its reliance on electricity requires consistent power supply. Additionally, initial setup might require technical support, particularly in settings with limited technical expertise.
Field Use of the Product
The YR02177 is invaluable in various clinical settings such as hospitals, clinics, and emergency departments. Its portability allows for flexible usage across different rooms and even in ambulatory situations. The combination of NIBP and SPO2 monitoring is especially beneficial in critical care units, enabling medical professionals to track vital signs continuously and respond promptly to any emergencies. This device supports medical teams in making informed decisions efficiently based on real-time data.
Recommendations
For optimal use of the YR02177, regular calibration checks are recommended to ensure ongoing accuracy of measurements. It’s also advisable to familiarize all operating staff with the device’s functionalities to prevent user errors. Ensuring the device is regularly serviced as per the manufacturer’s guidelines will help maintain performance levels and prolong its lifespan.
If you’re seeking a blend of innovation and quality, you have come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive laboratory equipment catalog. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life, it is time to be part of our community. https://kalstein.net/en/product/multi-parameter-patient-monitor-yr02177/.