Product Description
The Pulsed Xenon Lamp Benchtop Spectrophotometer YR05475 stands out for its cutting-edge technology and precision in color measurement. Engineered with a reflectance mode of d/8 and transmittance mode of d/0, it conforms with international standards including CIE No.15, ISO7724/1, and ASTM E1164. The spectrophotometer features an integrating sphere size of Φ 154mm, optimal for various measurement settings. Equipped with a 360-780nm Xenon Lamp, it offers a broad wavelength range, ideal for detailed analysis across the spectrum.
This model utilizes a concave grating spectrophotometric mode and a 256 Image Element Double Array CMOS Image Sensor, ensuring highly sensitive and accurate readings. The device supports multiple color spaces such as CIE Lab, XYZ, and Hunter LAB, along with advanced color difference formulas like ΔE*ab and ΔE*94. It offers automatic calibration with configurable apertures for both reflective and transmissive measurements, ensuring versatility and ease of use in diverse applications.
Technical Specifications
Model | YR05475 (Pulsed xenon lamp) |
Optical Geometry | Reflectance: d/8 (SCI⪰ Include UV/Exclude UV) |
Transmittance: d/0 (SCI⪰ Include UV/Exclude UV); Haze(ASTM D1003) | |
Conforms to CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724/1, ASTM E1164, DIN5033 Teil7 | |
Integrating Sphere Size | Φ 154mm |
Light Source Device | 360nm-780nm Xenon Lamp, 400nm cut-off Xenon Lamp |
Spectrophotometric Mode | Concave Grating |
Sensor | 256 Image Element Double Array CMOS Image Sensor |
Wavelength Range | 360-780nm |
Wavelength Pitch | 10nm |
Semiband Width | 5nm |
Reflectance Range | 0~200% |
Measuring Aperture | Reflective: Φ30mm/Φ25.4mm, Φ10mm/Φ8mm, Φ6mm/Φ4mm; |
Transmissive: Φ30mm/Φ25.4mm; Remark: 1. Automatic identification of switch caliber 2. Customized Configuration caliber and lens position | |
Specular Component | Reflectance: SCI&SCE |
Transmittance: SCI&SCE | |
Color Space | CIE Lab, XYZ, Yxy, LCh, CIE LUV, Hunter LAB, Munsell, s-RGB, HunterLab, DIN, βxy |
Color Difference Formula | ΔE*ab, ΔE*uv, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00v, ΔE(Hunter), DIN ΔE99 |
Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI (ASTM D1925, ASTM 313), MI (Metamerism Index), Staining Fastness, Color Fastness, Color Strength, Opacity, Gardner Index, Pt-Co Index, 555 Index, Haze(ASTM D1003) |
Observer Angle | 2° & 10° |
Illuminants | D65, A, C, UV, D50, D55, D75, F1, F2, F3, F4, F5, F6, F7, F8, F9, F10, F11, F12 |
Displayed Data | Spectrogram/Values, Chromaticity Values, Color Difference Values/Graph, Pass/Fail Result, Color Offset |
Measuring Time | About 2.4s (Measure SCI & SCE about 5s) |
Repeatability | Spectral reflectance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.06%) |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.015 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Spectral Transmittance: Φ25.4mm/SCI, Standard deviation within 0.07% (400 nm to 700 nm: within 0.07%) | |
Chromaticity value: Φ25.4mm/SCI, Standard deviation within ΔE*ab 0.018 (When a white calibration plate is measured 30 times at 5 second intervals after white calibration) | |
Inter-instrument Error | Φ25.4mm/SCI, Within ΔE*ab 0.15 |
(Average for 12 BCRA Series II color tiles) | |
Size | 370×300×200mm |
Weight | About 9.6kg |
Power Supply | DC 24V, 3A Power Adapter |
Light Source Device Life | 5 years, more than 3 million times measurements. |
Display | 7″ TFT Capacitive Screen-touch Display |
Data Port | USB & Print serial port |
Data Storage | Standard 2000 Pcs, Sample 20000 Pcs |
Language | Simplified Chinese, Traditional Chinese, English, |
Working Environment | Temperature: 0~40℃; Humidity: 0~85% (No Condensation) |
Storage Environment | Temperature: -20~50℃; Humidity: 0~85% (No Condensation) |
Standard Accessory | Power Adapter, User Guide, CD Disk (PC Software), USB cable, Standard Calibration Board, Black Calibration Cavity, Transmission black baffle, Sample holder, 25.4 caliber, 8 caliber, 4 caliber, |
Optional Accessory | Micro-printer, Transmissive Test Clamp Component, Micro Aperture(4mm) transmission test clamp component, Instrument inversion components |
Notes: The specifications are subject to change without notice. |
Market Price
The Pulsed Xenon Lamp Benchtop Spectrophotometer generally falls within the price range of 10,000 USD to 10,700 USD, reflecting its advanced technical capabilities and comprehensive feature set. This competitive pricing positions it well within the market for high-precision spectrophotometric instruments, making it an attractive choice for laboratories and research institutions seeking reliable color measurement solutions.
Frequently Asked Questions
What is the light source used in this spectrophotometer?
The spectrophotometer utilizes a pulsed xenon lamp with a wavelength range of 360-780nm, accompanied by a 400nm cut-off Xenon Lamp for precise measurement.
What types of measurements can this device perform?
It supports both reflective and transmissive measurements, adhering to SCI & SCE standards, and is compliant with colorimetric standards such as CIE, ASTM, and ISO.
How does the device ensure accurate color measurements?
The YR05475 model is equipped with a concave grating spectrophotometric mode and features a 256 Image Element Double Array CMOS Image Sensor, ensuring precise and sensitive readings across a wide range of color spaces.
Advantages and Disadvantages
Advantages: The Pulsed Xenon Lamp Benchtop Spectrophotometer offers exceptional wavelength coverage from 360 to 780nm, making it suitable for comprehensive color analysis across various applications. Its high repeatability and inter-instrument accuracy, highlighted by a ΔE*ab of just 0.15, ensure consistent results. Additionally, the user-friendly 7-inch TFT capacitive touchscreen enhances operational efficiency, while its robust data storage capability accommodates large datasets.
Disadvantages: The advanced nature of this equipment may require specialized training for optimal use, and the initial investment may be substantial for labs with limited budgets. Furthermore, while the device’s durability is commendable, its size and weight may pose a challenge for mobile laboratory settings.
Field Use
In practical scenarios, the Pulsed Xenon Lamp Benchtop Spectrophotometer is indispensable for laboratories focused on rigorous color quality control. It is extensively utilized in textiles, plastics, paints, and coatings industries, where precise color matching and differentiation are crucial. The device’s capability to switch seamlessly between reflective and transmissive measurements makes it ideal for versatile applications, from monitoring product consistency to researching new materials.
The instrument’s intuitive interface allows technicians to conduct rapid assessments with minimal setup time, enhancing laboratory throughput. Additionally, the robust construction and extensive lifespan of over 3 million measurements substantiate its suitability for high-demand environments.
Recommendations
For optimal performance, regular calibration using the supplied standard calibration board is recommended. Ensure the working environment remains within the specified temperature (0~40℃) and humidity (0~85%) ranges to prolong device life and maintain measurement integrity. Users are encouraged to explore the optional accessories, like the micro-printer and transmissive test clamp components, to expand the device’s functional capabilities further.
To maximize value, consider leveraging Kalstein Plus for automatic quotations and tailored purchase options, simplifying the acquisition process. Providing training for staff on advanced features will facilitate more effective deployment and utilization of the equipment’s full potential.
Si está buscando una fusión de innovación y calidad, has llegado al lugar correcto. En Kalstein te ofrecemos el lujo de explorar nuestro exclusivo catálogo de equipos de laboratorio. Fabricamos cada equipo con un nivel de excelencia. Nuestros canales de compra online, intuitivos y ágiles, están diseñados para su comodidad, asegurando los precios más amigables. No dude más, le damos vida a la ciencia, es hora de hacer parte de nuestra comunidad. https://kalstein.net/en/product/pulsed-xenon-lamp-benchtop-spectrophotometer-yr053405/.