Product Description
The Non-Contact Benchtop Spectrophotometer YR05480 is a trailblazer in the arena of precise color measurement, redefining standards with its advanced technical features. This state-of-the-art instrument incorporates a D/8 optical geometry (diffuse illumination, reception at 8°) that complies with multiple international standards, including CIE No.15 and ISO7724-1. Its unique non-contact test design allows accurate measurement of colors in liquids, sauces, and powders, making it indispensable for quality control in automated production lines.
The spectrophotometer excels with its full-spectrum LED and UV light sources, working in synergy with a concave grid mode and a 256-pixel dual-matrix CMOS image sensor. Such configuration spans a wavelength range of 400~700nm with a 10nm output, ensuring unparalleled precision. Its expansive measured reflectance range from 0-200% and customizable measurement apertures (default Φ20mm, customizable to Φ10mm) make it versatile across various applications.
Technical Specifications
Model | YR05480 |
Optical Geometry | D/8 (diffuse illumination, reception at 8°, SCI includes specular reflection light); Complies with CIE standard No.15, GB/T 3978, and more |
Features | Non-contact test between the test probe and the tested sample, accurate for liquids, sauces, powders; measurement time 0.2 to 1.5 seconds, software customization available |
Light Source | Full-spectrum LED light source, UV light source |
Spectrophotometric Mode | Concave grid |
Sensor | 256-pixel dual-matrix CMOS image sensor |
Wave Range | 400~700nm, 10nm output |
Measured Reflectance Range | 0-200% |
Measuring Aperture | Φ20mm (Φ10mm can be customized) |
Non-contact Distance | 3.0 mm (±0.2 mm) |
Sample Height | Unlimited thickness, only test probes are used |
Distance Adjustment Method | Fixed height according to actual sample |
Measuring Mode | Software customization function |
Locating | Camera location |
Color Space | Laboratory CIE, XYZ, Yxy, LCh, LUV CIE, Musell, s-RGB, HunterLab, βxy, DIN Lab99 |
Color Difference Formula | ΔE*ab, ΔE*94, ΔE*cmc(2:1), ΔE*cmc(1:1), ΔE*00, ΔE(Hunter), DINΔE99 |
Other Colorimetric Index | WI (ASTM E313, CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Index of metamerism MI, Stain resistance, color fastness, strength, opacity |
Observer Angle | 2°/10° |
Illuminant | D65, A, C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30) |
Data Shown | Spectrogram/values, sample chromaticity values, color difference/graphic values, color simulation, pass/fail result, configurable display tolerance |
Measuring Time | As fast as 0.2 seconds |
Data Storage | Sample mode + Quality control mode 18,000; Continuous statistical mode 30,000, totaling no more than 48,000 |
Repeatability | Spectral reflectance: within 0.1% of standard deviation; Chromaticity value: ΔE*ab within 0.03 (optimal measurement mode, same conditions) |
Error Between Instruments | Within ΔE*ab 0.2 (Average value from 12 mosaics of BCRA series Ⅱ) |
Method of Measurement | Single measurement, average measurement (2~99 times) |
Dimension | 200*200*160 mm (test probe) |
Weight | Approx. 3 kg (test probe only) |
Energy | AC 24V, power adapter power supply 3A |
Illuminating Life | 5 years, more than 3 million times measurements |
Monitor | 7-inch TFT color LCD, capacitive touch screen |
Data Port | USB, Bluetooth®5.0 |
Language | Simplified Chinese, Traditional Chinese, English |
Operating Environment | 0~40 ℃, 0~85 % RH (non-condensing), altitude: less than 2000 m |
Storage Environment | -20~50℃, 0~85%RH (no condensation) |
Standard Accessory | Power adaptor, manual, data cable, standard calibration plate, black calibration box |
Notes | Especially suitable for optimized production lines, deep customization of functions will incur additional costs |
Market Price
The pricing landscape for advanced spectrophotometers varies significantly, with the Non-Contact Benchtop Spectrophotometer YR05480 positioned competitively. The market price for this model can range between approximately 11,200 USD to 11,900 USD, reflecting its advanced features and precision engineering. This range is an approximation designed to help customers gauge the expected investment and ultimately realize the exceptional value this device delivers. We invite you to generate an automatic quote via the Kalstein Plus platform to explore potential exclusive offers and streamline your purchasing process.
Frequently Asked Questions
What is the primary use of the Non-Contact Benchtop Spectrophotometer YR05480?
This spectrophotometer is primarily used for precise and accurate color measurement in various industries, including automated production lines where non-contact interaction with the sample is critical.
Can the measurement time be adjusted?
Yes, it can be adjusted between 0.2 to 1.5 seconds, making it adaptable to different measurement needs and enhancing process efficiency.
Are there options for software customization?
Absolutely. The YR05480 allows for software functions to be tailored to specific requirements, although such customization needs to be evaluated and may incur additional costs.
Advantages and Disadvantages
The Non-Contact Benchtop Spectrophotometer YR05480 offers numerous advantages. Its non-contact capabilities eliminate the risk of sample contamination, making it ideal for a range of materials from liquids to powders. The high-speed processing time of just 0.2 seconds boosts productivity in batch processing environments.
One potential disadvantage is that deep customization options, although beneficial, may result in extra costs and time during setup. Additionally, while it is light and compact, it still demands a formal setup and calibrated environment to achieve optimal results.
Product Use in the Field
The Non-Contact Benchtop Spectrophotometer YR05480 is widely used across fields like food production, chemicals, and manufacturing, where precise color consistency is crucial. Operators skillfully manage this device by positioning samples at a fixed distance of 3.0 mm (±0.2 mm) and conducting rapid tests, which allow for dynamic monitoring and control over production quality.
In practice, its intuitive interface and capacity for data storage up to 48,000 items enable seamless integration into quality control processes. Frequent use cases involve tracking color fidelity in food products and ensuring product homogeneity in manufacturing setups, thereby reducing waste and increasing customer satisfaction.
Recommendations
To maximize the capabilities of the YR05480 Spectrophotometer, users should ensure an environment free from extreme temperatures and humidity, adhering to an operational range of 0~40℃ and 0~85% RH. Regular calibration using the provided standard calibration plate ensures sustained accuracy.
For longevity and consistent performance, ensure that software updates through USB or Bluetooth® connections are regularly applied. As a best practice, engage with the Kalstein support team for any advanced setup and calibration needs to expand the instrument’s utility further with customized software features.
If you’re seeking a blend of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer; we bring science to life—it’s time to become a part of our community. https://kalstein.net/en/product/non-contact-benchtop-spectrophotometer-yr05480/.