Product Description
The Clinical Refractometer YR05915 is a beacon of precise measurement, employing advanced optical technology to provide accurate readings crucial for clinical settings. This device is engineered to measure the refractive index and specific gravity of various solutions with exceptional precision. With its compact design, the refractometer is crafted from pure aluminum, ensuring robustness and lightweight portability. Its capacity for automatic temperature compensation (ATC) enhances its usability by maintaining accuracy across temperature fluctuations from 10-30° C.
The YR05915’s measurement range is from 0-12g/dl, with specific gravity readings of 1.000-1.050sg and refractive index readings of 1.3300RI-1.3600RI. The instrument’s precision is underscored by its minimal division of 0.2g/dl for concentration, 0.001 SG for specific gravity, and 0.001 RI for refractive index, ensuring reliable results for even the most minute variables. The accuracy of ±0.2g/dl, ±0.001 SG, and ±0.001 RI further heightens the dependability of its measurements, making it an indispensable tool for laboratories focused on quality control and analytical diagnosis.
Model | YR05915 |
Description | ATC Clinical 0-12g/dl 1.000-1.050sg 1.3300RI-1.3600RI optical refractometer |
Measurement Range | 0-12g/dl 1.000-1.050sg 1.3300RI-1.3600RI |
Min. Div. | 0.2g/dl 0.001 SG 0.001 RI |
Accuracy | ±0.2g/dl ±0.001 SG ±0.001 RI |
ATC | Yes |
ATC Temp. | 10-30° C |
Material | Pure aluminum |
Market Price
In the competitive market of clinical refractometers, the YR05915 positions itself as a cost-effective yet high-performance option. The average price range for similar products spans from approximately 70 USD to 210 USD, providing a budget-friendly yet reliable choice for laboratories and clinical settings. This positioning ensures that buyers are investing in quality and precision without compromising on economic prudence. For those interested in acquiring innovative laboratory tools, the refractometer YR05915 stands as a prudent choice that blends cost and performance.
Frequently Asked Questions
What is the significance of automatic temperature compensation (ATC)?
ATC ensures that measurements remain accurate regardless of changes in ambient temperature, making the instrument more reliable under varying conditions.
How do I maintain my clinical refractometer?
Regular cleaning with a soft, dry cloth and avoiding exposure to harsh chemicals will prolong the device’s lifespan and ensure consistent performance.
Can this refractometer measure different types of solutions?
Yes, the YR05915 is versatile and can accurately measure a variety of solutions, making it suitable for diverse applications in clinical environments.
Advantages and Disadvantages
The Clinical Refractometer YR05915 offers numerous advantages that make it a preferred choice in laboratory settings. Its highlights include high accuracy, portability due to its lightweight aluminum construction, and the benefit of automatic temperature compensation. However, like any product, it may have limitations. Users should be cautious of exposure to extreme conditions or chemicals that may damage its optics or body. While it excels in laboratory settings, users must adhere to regular maintenance to ensure sustained accuracy and performance.
Field Usage
The YR05915 is particularly formidable in environments where precision is paramount. In laboratory scenarios, it serves as an indispensable tool for calculating precise measurements of solution concentrations, vital in diagnosis and quality control. Its robust design makes it ideal for fieldwork, extending its utility beyond traditional laboratory applications. Moreover, calibration procedures are straightforward, enhancing its usability for technicians who must switch between varying conditions and measurement tasks with ease.
Recommendations
To maximize the efficiency and longevity of the YR05915 refractometer, it is essential to follow certain guidelines. Regularly calibrate the instrument according to the manufacturer’s instructions to maintain its precision. Store the refractometer in a dust-free environment to protect its optical components and avoid contact with liquids that might interfere with measurements. When using the device, ensure the test samples are clean to avoid cross-contamination. Following these practices will ensure the refractometer delivers consistent, reliable results, making it an asset in any scientific setting.
Take the next step in enhancing your lab’s precision today by exploring the benefits of the Clinical Refractometer YR05915. You can easily request a quote or generate an automatic estimate through the Kalstein Plus platform.
If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and fast online shopping channels are designed for your convenience, ensuring the most friendly prices. Don’t hesitate any longer, we give life to science; it’s time to become part of our community. https://kalstein.net/en/product/clinical-refractometer-yr05915/.