Product Description
The Fully Automated Slide Stainer YR436-1 stands as a beacon of precision and innovation in the laboratory equipment sphere. Designed to streamline and enhance the histological staining process, this fully automated system is engineered to meet the demanding needs of modern laboratories. Its intricate design includes 15 tanks, with one designated for drying, another for washing, and 13 dedicated to reagents, providing rigorous control and flexibility in staining procedures.
Each tank can hold approximately 350 ml, ensuring ample reagent availability for various staining protocols. The equipment boasts adjustable treatment durations, with a time span ranging from 0 to 59 minutes and additional adjustments in 59-second increments, meeting diverse procedural requirements. With a remarkable temperature control accuracy of ± 1%, this device guarantees consistent results, enhancing the reliability and reproducibility of laboratory workflows.
Model | YR436-1 |
Number of tanks | 15 (station 1 is for drying, station 2 for washing and the 13 other stations for reagents) |
Capacity of each tank | about 350 ml |
Duration of treatment in the tank | adjustable between 0 and 59 minutes and between 0 and 59 seconds |
Accuracy of temperature control | ± 1% |
Dripping time | adjustable between 0 and 60 seconds |
Stirring frequency | adjustable between 0 and 6 times / minute |
Working voltage | AC220V ± 10% 50Hz (standard model); AC110V ± 10% 60Hz |
Power | 400W |
Dimensions | 925 × 250 × 260 mm (L × P × H) |
Weight | 27 kg |
Market Pricing
For those considering acquiring the YR436-1 Automated Slide Stainer, it’s important to be aware of the market pricing landscape. This advanced piece of equipment is generally available within a price range from approximately $6,000 to $7,000. While the initial investment might seem substantial, the efficiency and precision it brings to laboratory operations justify the cost, presenting long-term value and reliability.
The device’s engineering excellence, coupled with its user-friendly interface, makes it an appealing choice for both large laboratories and smaller operations aiming to modernize their staining processes. However, those interested in this stainer should consider reaching out directly to Kalstein for a detailed quote catered to their specific needs and potential bulk pricing advantages.
Frequently Asked Questions
What are the power requirements for this device?
The YR436-1 operates on a working voltage of AC220V ± 10% at 50Hz for the standard model, with an alternative option for AC110V ± 10% at 60Hz. This flexibility allows for its use in various international settings.
How does the stainer handle temperature control?
Temperature control is precise, with an accuracy of ± 1%, ensuring consistent and reliable staining results across different runs.
Can the device service multiple slides simultaneously?
Yes, the tank capacity and the distinct station allocation for drying and washing enhance its efficiency, facilitating the simultaneous processing of multiple slides with varying reagent needs.
Advantages and Disadvantages
Advantages: The YR436-1 Automated Slide Stainer is highly versatile, capable of accommodating customized staining protocols due to its adjustable treatment durations and reagent handling efficiency. The precision in temperature control enhances reproducibility, while its extensive tank capacity promotes workflow efficiency in laboratories.
Disadvantages: As with any advanced technological equipment, there is a learning curve associated with its use. Laboratories need to ensure proper staff training to fully utilize the device’s capabilities. Additionally, the initial investment cost may be a consideration for some facilities, though the long-term benefits often outweigh this initial expenditure.
Field Usage of the Product
In practical settings, the YR436-1 is an indispensable tool in both research and clinical laboratories. Slide staining, a critical process in histopathology, is expedited significantly through automation. This device ensures uniform staining, reducing human error associated with manual techniques and accelerating diagnostic workflows.
Specifically, in high-throughput laboratories, the ability to handle multiple slides concurrently is invaluable, significantly cutting down on turnaround time while ensuring high-quality results. The use of this slide stainer has shown to improve productivity significantly, allowing researchers and clinicians to focus on analytical tasks rather than the procedural nuances of the staining process.
Recommendations
To maximize the utility of the YR436-1 Automated Slide Stainer, it is advisable for laboratories to maintain a rigorous maintenance schedule, ensuring that all tanks and components are cleaned regularly to avoid cross-contamination. Staff should be adequately trained not only in operating the device but also in troubleshooting common issues.
Given its significant capabilities, laboratories should consider integrating the YR436-1 into digital lab management systems for enhanced efficiency. This integration allows for precise scheduling and usage data logging, optimizing both the device’s performance and the laboratory’s operational workflow.
If you’re seeking a fusion of innovation and quality, you’ve come to the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. Each piece of equipment is crafted with excellent standards. Our intuitive and agile online purchase channels are designed for your convenience, ensuring the most competitive prices. Do not hesitate any longer; we bring science to life. It’s time to become part of our community. https://kalstein.net/en/product/fully-automated-slide-staining-yr436-1/