The YR03732 pipette series stands as a hallmark of precision and reliability in liquid handling. Designed for laboratories that demand exactitude and consistency, this series covers a wide range of volume specifications to suit various scientific applications.

The models in the series include:

  • YR03732: Volume Range 0.1 – 2μl, Accuracy ±12.0 – 1.5%, Repeatability ≤6.00 – 0.70%
  • YR03732-1: Volume Range 0.5 – 1μl, Accuracy ±2.5 – 1.0%, Repeatability ≤1.50 – 0.40%
  • YR03732-2: Volume Range 2 – 20μl, Accuracy ±2.5 – 1.0%, Repeatability ≤1.50 – 0.30%
  • YR03732-3: Volume Range 5 – 50μl, Accuracy ±2.0 – 1.0%, Repeatability ≤1.50 – 0.25%
  • YR03732-4: Volume Range 10 – 100μl, Accuracy ±1.8 – 0.8%, Repeatability ≤0.50 – 0.15%
  • YR03732-5: Volume Range 20 – 200μl, Accuracy ±1.8 – 0.6%, Repeatability ≤0.50 – 0.15%
  • YR03732-6: Volume Range 100 – 1,000μl, Accuracy ±1.5 – 0.6%, Repeatability ≤0.30 – 0.15%
  • YR03732-7: Volume Range 500 – 5,000μl, Accuracy ±1.2 – 0.6%, Repeatability ≤0.30 – 0.15%
  • YR03732-8: Volume Range 1 – 10ml, Accuracy ±2.5 – 0.6%, Repeatability ≤0.30 – 0.15%

Technical Specifications

Model Volume Range Accuracy Repeatability
YR03732 0.1 – 2μl ±12.0 – 1.5 % ≤6.00 – 0.70%
YR03732-1 0.5 – 1μl ±2.5 – 1.0 % ≤1.50 – 0.40%
YR03732-2 2 – 20μl ±2.5 – 1.0 % ≤1.50 – 0.30%
YR03732-3 5 – 50μl ±2.0 – 1.0 % ≤1.50 – 0.25%
YR03732-4 10 – 100μl ±1.8 – 0.8% ≤0.50 – 0.15%
YR03732-5 20 – 200μl ±1.8 – 0.6% ≤0.50 – 0.15%
YR03732-6 100 – 1,000μl ±1.5 – 0.6% ≤0.30 – 0.15%
YR03732-7 500 – 5,000μl ±1.2 – 0.6 % ≤0.30 – 0.15%
YR03732-8 1 – 10ml ±2.5 – 0.6 % ≤0.30 – 0.15%

Market Price

The YR03732 pipette series is competitively priced within the laboratory equipment market. The typical price range for these precision instruments varies between 150 USD to 450 USD, offering exceptional value for the precision and reliability they provide. This broad range ensures that laboratories of varying budgets can access top-notch pipetting technology without compromise.

By opting for the YR03732 series, labs can expect not only exceptional performance but also a cost-effective solution that aligns with their financial considerations. Thus, choosing these pipettes means opting for a blend of quality, affordability, and precision.

Frequently Asked Questions

What is the primary use of the YR03732 pipette series?

The YR03732 pipette series is used for precise liquid handling in various laboratory settings, including molecular biology, biochemistry, and clinical diagnostics.

Are these pipettes easy to calibrate?

Yes, the YR03732 pipette series is designed for easy calibration and maintenance, ensuring ongoing accuracy and reliability.

What material is used for the construction of the pipettes?

The pipettes are made from durable, high-quality materials designed to withstand regular sterilization and extensive use in lab environments.

Advantages and Disadvantages

Advantages:

  • Excellent precision and accuracy across a wide volume range.
  • User-friendly design for comfort during extended use.
  • Robust construction ensures durability and long service life.

Disadvantages:

  • Initial setup may require some familiarization for optimal use.
  • The precision components require careful handling and maintenance.

Field Use of the Product

In the field of molecular biology, the YR03732 pipette series proves indispensable for applications requiring precise measurement of reagents. Whether performing a delicate serial dilution or pipetting enzymes in a PCR setup, these pipettes ensure high accuracy and reproducibility, essential for reliable experimental results.

In clinical laboratories, these pipettes aid in the preparation of samples and reagents, where consistency and reliability can significantly impact diagnostic outcomes. Their ergonomic design facilitates hours of continuous use without causing operator fatigue, thereby improving workflow efficiency.

Recommendations

To extend the lifespan of your YR03732 pipettes, regular maintenance and calibration are recommended. Ensure that the pipette is properly cleaned after use and stored in a vertical position to prevent damage to the internal components. Additionally, operators should be trained in proper pipetting techniques to maximize accuracy and reduce wear.

For optimal performance, pair your YR03732 pipettes with high-quality tips recommended by the manufacturer. Regularly checking and recalibrating your instruments will help maintain their precision and ensure the integrity of your laboratory results.

If you are looking for a fusion of innovation and quality, you have come to the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each piece of equipment with a level of excellence. Our intuitive and agile online purchasing channels are designed for your convenience, ensuring the friendliest prices. Do not hesitate any longer, we bring science to life; it’s time to become part of our community. https://kalstein.net/en/product/liquid-handling-pipettes-yr03732-yr03732-8/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]