Unraveling Precision: The YR01830 Benchtop TDS Conductivity Meter

Product Description

The YR01830 Benchtop TDS Conductivity Meter stands out as a sophisticated tool engineered for precision measurements in diverse laboratory settings. Renowned for its cutting-edge technology, this device ensures reliable and accurate results for the measurement of various parameters including conductivity, TDS, salinity, and resistivity. The measuring range varies impressively, accommodating different scientific needs with conductivity ranging from 0.00 μS/cm to 200.0 mS/cm and TDS capable of measuring up to 100 g/L.

This meter is equipped with a robust resolution of 0.01 to 1 μS/cm and mS/cm, ensuring fine-tuned readings that are critical for scientific research and industrial applications alike. Its accuracy is unparalleled with the meter boasting a ±1.50% FS, and the electrode a close ±1.0% FS, demonstrating the device’s ability to deliver precision. Furthermore, it includes an automatic temperature compensation range from 0 to 50ºC ensuring consistent performance even under fluctuating environmental conditions.

Model YR01830
Conductivity Measuring range (0.00~20.00)μS/cm; (20.0~200.0)μS/cm; (200~2000)μS/cm; (2.00~20.00)mS/cm; (20.0~200.0)mS/cm
TDS (0~100) g/L
Salinity (0 ~ 100)ppt
Resistivity (0 ~ 100)MΩ·cm
Resolution 0.01/0.1/1μS/cm; 0.01/0.1mS/cm
Accuracy Meter: ±1.50% FS; Electrode: ±1.0% FS
Temp. compensation range (0 ~ 50)ºC , auto
Electrode constant 0.1 / 1 / 10 cm-1
Temperature Measuring range (-10 ~ 110)ºC
Resolution 0.1ºC
Accuracy 5~ 60ºC: range: ±0.5ºC; other range: ±1.0ºC
Other Technical Parameters Display 5-Inch white backlit LCD screen
Data storage 300 sets
Power DC 5V/1A
Communication connector Micro USB & Standard USB
Dimension/N.W. 180 x 130 x 14mm/280g
Working Condition Environment Temp. 5 ~ 35 ºC
Environmental ≤85%
IP Grade IP54

Market Price

The market price for sophisticated lab equipment like the YR01830 Benchtop TDS Conductivity Meter varies based on factors such as technological advancements and manufacturer pricing strategies. On average, potential buyers can expect a price range between $500 USD and $1,600 USD, reflecting the innovations incorporated into this model and the reliability it offers for laboratory environments.

Frequently Asked Questions

What are the main features of the YR01830 Benchtop TDS Conductivity Meter?

The YR01830 features a wide measuring range for conductivity, advanced temperature compensation, a high-resolution display, and versatile data storage capabilities.

Is the YR01830 suitable for fieldwork?

Although primarily designed for benchtop use, the YR01830’s robust build and IP54 rating make it a resilient choice for controlled field environments with proper protective measures.

What power supply does the YR01830 require?

The device operates efficiently on a DC 5V/1A power supply.

Advantages and Disadvantages

Advantages: The YR01830 excels in precision with a broad measurement range and exceptional accuracy. Its user-friendly interface, enhanced by a white backlit LCD screen, facilitates data reading and navigation. The storage capacity for 300 data sets is a notable advantage for prolonged research applications.

Disadvantages: The device’s benchtop design may limit portability for extensive fieldwork. Moreover, it requires careful calibration and maintenance to ensure prolonged accuracy, potentially requiring additional efforts from users unfamiliar with setup procedures.

Product Use in the Field

In laboratory settings, the YR01830 proves indispensable for quality control and research applications across chemical, environmental, and agricultural industries. Researchers often utilize its precise conductivity measurements to monitor solvent purity and water quality, ensuring compliant standards in diverse experimental setups.

In field scenarios, with proper environmental controls, the meter’s reliable readings contribute to critical water quality assessments and TDS evaluations in remote locations. The device’s automatic temperature compensation further enhances its usability by adapting to varying ambient temperatures seamlessly.

Recommendations

To optimize the utility of the YR01830 Benchtop TDS Conductivity Meter, it is recommended to regularly calibrate the device following the user manual’s guidance. Utilize certified calibration solutions to maintain the device’s accuracy over time.

Additionally, consider using the meter within its recommended operating conditions to maximize lifespan and performance. Encourage team members or users to undergo proper training on device handling and maintenance protocols to ensure consistent and efficient use across all applications.

If you are in the quest for a blend of innovation and quality, you have arrived at the right place. At Kalstein, we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our intuitive and agile online shopping channels are designed for your convenience, guaranteeing the friendliest prices. Don’t hesitate any longer, we bring science to life; it’s time to become part of our community. https://kalstein.net/en/product/yr01830-benchtop-tds-conductivity-meter/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]