YR01858 Double Beam UV-Vis Spectrophotometer: Precision at Its Best

Product Description

The YR01858 Double Beam UV-Vis Spectrophotometer is a state-of-the-art instrument designed for precise analytical measurements across a broad range of applications. Featuring a wavelength range of 190-1100nm, it is equipped to handle a diverse spectrum of samples, making it indispensable in both clinical and laboratory environments.

This spectrophotometer is engineered with a 2nm spectral bandwidth, ensuring high-resolution measurements. Its wavelength accuracy stands at ±0.5nm, with stray light at a minimal 0.05% T at 220 nm and 360 nm, guaranteeing the integrity of your results. Additionally, the device offers a wavelength repeatability of ≤0.1nm, enhancing reliability across repeated measurements.

Model YR01858
Wavelength Range 190-1100nm
The spectral bandwidth 2nm
Wavelength Accuracy ±0.5nm
Stray light 0.05% T @ 220 nm, 360 nm
Wavelength Repeatability ≤0.1nm
Photometric Accuracy 士0.2%T(0-100%T)

±0.002Abs(0-0.5Abs)

±0.004Abs(0.5-1.0Abs)

Photometric Repeatability ≤0.1%T(0-100%T)

0.001Abs(0-0.5Abs)

0.002Abs(0.5-1.0Abs)

Stability 士0.001A/h@500nm
Photometric Range 0-200%T, -0.3-3.0A, 0-9999C
Baseline flatness 士0.001A
Noise ±0.0005A
Display 800*480 touch screen
Data Output Port USB
Print Port USB Port
Light source Tungsten Lamp & Deuterium Lamp
Power Requirements AC 220V/50Hz or AC 110v/60Hz
Detector Silicon Photodiode
Dimension 460*380*180mm
Weight 20KG

Market Price

The YR01858 Double Beam UV-Vis Spectrophotometer represents a significant investment in quality and analytical precision. In the current market, the price for sophisticated units like these typically ranges from $5000 to $6400. Investing in this device means equipping your lab with top-tier technology that ensures accurate results, reducing the risk of errors in your analysis.

Frequently Asked Questions

What kind of light sources does the spectrophotometer use?

The YR01858 model uses both Tungsten and Deuterium lamps, providing a wide range of light essential for accurate measurements across various wavelengths.

Is this spectrophotometer suitable for clinical use?

Yes, the YR01858 Double Beam UV-Vis Spectrophotometer is extensively used in clinical laboratories due to its precision and reliability in obtaining accurate measurements.

How does the USB data output benefit me?

The USB data output allows for easy transfer of data to computers for further analysis and documentation, streamlining the workflow in both research and clinical settings.

Advantages and Disadvantages

Advantages: The YR01858 spectrophotometer boasts high precision with wavelength accuracies and photometric repeatabilities that assure consistency in results. Its user-friendly interface facilitated by an 800*480 touch screen enhances operational convenience. Additionally, dual light sources allow comprehensive spectral analysis while minimizing noise to ±0.0005A for clarity.

Disadvantages: Despite its numerous benefits, the spectrophotometer requires careful maintenance. The sophisticated technology demands regular calibration and may require expert handling to maximize its utility. The initial investment could be significant, but it is justifiable by its performance and longevity.

Applications in the Field

This spectrophotometer finds extensive application in environmental monitoring, pharmaceuticals, quality control, and biochemical research. Its broad wavelength range and accuracy make it suitable for quantifying nucleic acids, proteins, and other analytes, providing critical data to researchers. Whether used in determining the concentration of DNA or analyzing protein structures, this device offers precise readings essential for scientific advancement.

In quality control labs, it is pivotal for validating the purity of products and intermediates, helping maintain industry standards. Clinical labs make routine use of this spectrophotometer in diagnostics, where accuracy and reliability are imperative.

Recommendations

To maximize the performance of the YR01858, regular calibration and maintenance are essential for sustaining its accuracy. Users are advised to routinely check and replace light sources and ensure the spectrophotometer’s software is updated to the latest version for optimal functionality.

Ensuring a clean and controlled environment reduces the risk of external factors affecting the light path, thus preserving the integrity of measurements. Engaging with user training sessions can also enhance handling efficiency, promoting longer device lifespan.

If you are seeking a merger of innovation and quality, you’ve arrived at the right place. At Kalstein we offer you the luxury of exploring our exclusive catalog of laboratory equipment. We manufacture each device with a level of excellence. Our online purchase channels, intuitive and agile, are designed for your convenience, ensuring the most friendly prices. Do not hesitate any longer, we bring science to life, it’s time to become part of our community. https://kalstein.net/en/product/double-beam-uv-vis-spectrophotometer-yr01858/.

We are here to help you

Send us a direct message

If you require a quote, you have a question about any product and / or want to clarify any doubt, contact us.

    PARIS

    Headquarter

    5 rue de Castiglione 75001 Paris – France.
    (+33) 01 70 39 26 50 (Line available in English and French languages)
    (+33) 7 60 83 92 83 (Line available in Spanish and French languages)
    Mail: [email protected]